Germany, Neuenrade
... as variants in which the CSN® Current Sensor will be mounted hanging in the busbar. Schniewindt has implemented CSN® Current Sensors for nominal currents of up to 5 kADC at system voltages of 800 kVDC, which have been successfully typetested. Also for the precise measurement of small currents (1 to 10 A), such as transient currents in capacitor banks, Schniewindt offers appropriate solutions. All of our CSN® Current Sensors are individually designed according to customer requirements. ...
Germany, Donaueschingen
...NTC temperature sensors coated with epoxy resin have a very low temperature tolerance classification and a wide measuring range of -40…+150 °C. Name:NTC temperature sensor Sensor:NTC Temperature measuring range:-40...+150 °C Nominal resistance:1 kΩ Resistance tolerance:±1% Response time temperature:1 s in liquids Housing:Epoxy resin coated Beta constant:3348 K ±1.0% Self heating:0.85 mW/K...
... components on the sensor housing, including the end faces, must be avoided. The measuring element consists of a membrane that lies perpendicular to the sensor axis, on the inner side of which a full bridge of strain gauges is applied, expecting a stable supply voltage and having a nominal value of approximately 1 mV/V. The connection cable is routed radially out of the housing through a sleeve that...
Germany, Buchenbach
...Nominal value indicator compatible with bus system for monitored tool or format changes. With additional LED for clear indication of positioning status. It is used to monitor format changes, reduce setup times, and increase machine efficiency. Nominal value indicator with bus interface without real value measurement. Large control button for confirmation. Backlit display optimally readable. Two-line LCD display. Integrated RS485 interface, optional CAN Bus. User guidance via bicolor status LEDs. Protection rating IP53, optional IP65.
Switzerland, Rossens
... and counterclockwise directions, all with great accuracy. The sensor measures reaction torque through a flange-to-flange connection, in line with the component under test. Its mechanical design with a central through hole allows for easy passage of shafts, cables, or pipes. The main applications of the sensor include testing actuators, valves, fasteners, pumps, and brakes in the automotive sector, industry, or other fields. Nominal torque: 200 N·m ... 100 kN·m (or more) High precision: 0.05% ... 0.2% Allowable overload: up to 200% Protection class: IP65...
Belgium, Jumet
... zero signal (% F.S.*/10°C):< 0.1 Zero signal (V):5 Safe load limit (% F.S.*):130 Power supply (-):5...28 VDC Consumption (max.) (mA):37...45 Nominal sensitivity (V):± 4 Start-up current (mA):< 100 IP rating (-):IP50...
... of internal seals, they are ideal for test series with large numbers of load cycles where an interruption, e.g. due to the replacement of internal seals, is not permitted. Specific torque [Nm/bar]:8,16 Operating pressure [bar]:280 Nominal torque [Nm]:2285 Swivelling angle [ degrees° ]:120...
... Nominal orifice:0.5 mm Kv-value:0.11 l/min Size:10 mm Type of electric connection:Wire  Medium:Filtered (5 µm), lubricated and non lubricated air  Nominal power:3.2 W Nominal voltage:24 V DC Type of pneumatic connection:Flange  Returning mechanism:Spring  Ambient temperature:-10 ... +50 °C Materials:Base: PBT, seal: NBR  Valve type:Poppet valve ...
Germany, Ortenburg
Micro-Epsilon stands for innovation and continuity, as well as for sustainable growth and the pursuit of greater precision. The portfolio includes sensors for displacement, distance, position, thickness, 2D/3D measurement technology, laser scanners, micrometers, fiber optic sensors, sensors for color detection and color measurement, infrared temperature sensors, thermal imaging cameras, sensors fo...
Switzerland, Ebnat-Kappel
...Bondable platinum 1000 Ohm RTD component Nominal resistance 1000 Ω at 0 °C Operating temperature range —50 °C to +150 °C TCR Pt 3850 ppm/K Chip size/dimensions 0.75 x 0.75 x 0.3 mm Tolerance/class IEC 60751 F0.3 (IST AG tolerance class B) Connection type Bondable pads (Au) Packaging Chip tray, sensor-side up...
Germany, Winterbach
...durable actuators that are optimally tailored to the demanding applications of our customers. For technical inquiries and custom special designs, our qualified staff is happy to advise you and develop innovative fitting solutions. Product Overview - Single-acting and double-acting actuators - Numerous compatible accessories: solenoid valves, limit switch boxes, sensors, limit switches, etc. Discover our extensive range in the current WESA catalog. We would be happy to provide you with a customized offer.
Germany, Thierstein
... as a high overload and temperature resistance. Features: — nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar — accuracy: 0.25 % (opt. 0.1 %) FSO — shipping approvals: American Bureau of Shipping (ABS), Bureau Veritas (BV), China Classification Society (CCS), Det Norske Veritas (DNV), Germanischer Lloyd (GL), Lloyd's Register (LR) — high overpressure resistance — excellent accuracy — accuracy: 0.25 % (opt. 0.1 %) FSO Optional Features: — IS-Version Ex ia = intrinsically safe for gases and dusts — diaphragm AI2O3 99.9 %...
Germany, Schwerin
... materials: PMMA, optional: PEEK™; valve: PEEK™, FFPM optional: PPS, FPM, EPDM; volume flow sensor: borosilicate Seal materials: FPM, optional: EPDM, FFPM Electronics: ARM Cortex M3 microprocessor Motor: brushless DC-motor (BLDC); nominal voltage 24 V, torque 3.3 mNm; analog hall sensors Electrical connection: D-sub plug, 15-pole (male connector) Power supply: 24 V DC ±10 %, max. 1.5 A Interface: RS-232...
... sensors zero offset can be adjusted with the aid of the offset trimmer on the rear of the device Display:3½-digit, red, 10 mm high LED display. Sampling frequency:approx. 3 measurements / sec. Operating temperature:0 to 50 °C (permissible ambient temperature) Relative humidity:5 to 95% r.h. (non-condensing) Storage temperature:-20 to 70 °C Power supply:8–20 V DC or 18–29 V DC (standard) (can be...
Germany, Duisburg
... the liquid and are therefore insensitive to floating grease and oil on the surface. Application::for MID for partially filled pipelines Technology::magnetic-inductive Additional features::series Process temperature:0...+60°C / +32...+140°F Measuring range:-12...+12 m/s / -40...+40 ft/s Nominal diameter:DN200...1600 / 8...64"...
Germany, Gschwend
... very good reproducibility is less than one percent of the nominal load. The sensor is available in measuring ranges from 20 up to 2000 kN. Hardened washers are already included in the scope of delivery for quick and easy installation. The extremely simple and robust design is made entirely of stainless steel (protection class IP68).
Spain, Paterna
...The high-quality humidity sensors, modules, probes, and transmitters from SENSOVANT have been tested in most industrial applications for decades. We offer the widest range of instrumentation for the precise measurement of humidity in the following fields: • Industrial: Maximum precision across a wide range of temperatures. Versions available for nominal pressure applications, intrinsically safe...
Germany, Offenbach
...Product Family: iDim Space Solutions Active+ Installation: For Luminaire Sensors: PIR Motion Sensor, Light Sensor PIR Motion Sensor Detection Angle (°): 80 Nominal Installation Height (m): 3 Detection Range (m): 5 Light Sensor...
Belgium, Brussels
... Sensor, Pyrometer (depending on the version) External Sensors: Via specific connector (Lemo 7 pin connector) Memory: – 20 Measurement Nodes (measurement points) Communication: USB Interface Battery*: Rechargeable Battery: 8 cell, 4.8 V, NiMH (Nickel Metal Hydride) Nominal Capacity: 4.4 Ah Software for data transfer to PC: DataDump Application Auto Shutoff: Auto shutoff after a preset time...
Italy, Santa Maria Capua Vetere
... agent (rain); In dry condition the value of the capacitor is nominal 100pF, In presence of the rain the capacitance goes to high valued respect the dry contidion; The ratio changing is over 420%, in the table N.1 you can verify the capacitance change characteristics. On Face B is present the heating circuit the temperature sensor (NTC component) and the connection interface (six pads).
Austria, Rohrau
...The LxxxT-28 current sensor is a completely new development from GWP, which enables the advantages of sensor technology also for the low voltage area. The design is made for installation on low voltage cables either isolated or not isolated. It combines a wide range behaviour with low costs. The usage of correction factors enables even better corrections in combination with dedicated devices...
...Optimized dead space, flush-mounted turbidity meter for media with a minimum turbidity of 2000 NTU. » Flush-mounted, hygienic sensor » For medium and high turbidity (e.g., milk, yeast) » Wear-free LED technology, no color dependence (wavelength 860 nm) » Ideally suited for the requirements of the food industry » No influence from reflections at small nominal diameters » Usable from DN 25 » High...
France, Nassandres
... cleaning performance. Application: brush cleaning Volume: 60 l Material: plastic Working surface width: 790 mm Working area depth: 520 mm Working surface height: 870 mm External length: 620 mm External width: 890 mm External height: 880 mm Total permissible load: 200 kg Color: anthracite / blue Nominal voltage: 230 V Operating temperature: 41 °C Certification: CE Weight: 45 kg...
Slovakia, Bratislava
... diameter I stage:140mm Cylinder diameter II stage:80mm Compressor shaft rotation frequency (nominal):1470 RPM Cooling:air Terminal pressure:7-9 Lubrication:Combined: under pressure and spray Pressure in lubricating system:1,7...3 Drive:From electric engine or internal combustion engine through elastic coupling Oil quantity filled into compressor:5,5 Consumed power at backpressure 7 kgf/cm 2 and rated rotation frequency:22.75 kW...
Germany, Ingelfingen
... different nominal sizes with various connection options and up to 12 valves. By simply rotating the valve insert, each valve can be converted from collector function to distributor function - or vice versa. All valve positions can also be equipped with supplementary modules instead of valves (e.g., with temperature sensors). - Plug-in coil system AC10 - Series valve 2, 3, 4-fold, hose connection - Housing plastic DN10 …DN13...
Germany, Hallbergmoos
...IEC 61672-1 Ed. 2.0 (2013) (0° and 90° reference direction); IEC 61620 (1995) NF EN 61260/A1 (2002); S Dynamic Range: 21-138 dB (A, B), 26-138 dB (C), 31-138 dB (Z), 1 single range for nominal sensitivity of 50 m Linear Operating Range for A-Weighting: 5 Frequencies: 31.5 Hz: 26-97 dB; 1 kHz: 24-137 dB; 4 kHz: 24-137 dB; 8 kHz: 24-133 dB; 12.5 Peak Dynamic Range: 61-140 dBC, 1 single range Time...
Switzerland, Bubendorf
...The system measures crystallization, cell density growth, or monitors filtration or condensate. The ATM100 allows for a 6-point linearization per channel. Up to four measurement points can be operated via the bus. From sensors made of stainless steel 316L with fiber optics and remote coupling electronics to built versions in various nominal sizes, almost anything is possible. The summed signal is high-resolution and sensitive due to the optical receiver lens.
Germany, Kirchzarten
... measurement system for 64 rotations makes any tedious reference travel unnecessary; thus, the machine's efficiency is increased. The cost-effective DC motor also allows for automation tasks that were previously not viable due to associated costs. Individual supply voltages for the control and power electronic systems enable an emergency stop function without interrupting communication with the control. Nominal torque / Nominal speed: 1 .. 2 Nm / 80 .. 20 rpm Degree of protection: IP 54 Output shaft: Hollow shaft of 8 mm with clamping ring Bus communication: CANopen, DeviceNet, Modbus RTU...
France, Huningue
...Power supply for a 4-wire sensor or transmitter. The power supply has an output for powering 4-wire sensors and transmitters. It can be connected to a single-phase network or to 2 phases of a three-phase network (TN, TT, or IT networks according to VDE 0100 T 300/IEC 3643) with a nominal voltage of 100-240 V AC.
...Nominal force 10 kN axial compressive load; Stroke 800 mm (spring drive); freely programmable digital control; automatically running programmed test processes and their evaluation using force and displacement sensors.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play