...Wi-CoRe is an innovative wireless control relay specifically engineered to enable seamless integration between WiT-es and WiPr-es sensors and industrial control systems. It is designed for applications requiring continuous monitoring and real-time temperature and pressure-based adjustments in various industrial settings. Wi-CoRe simplifies temperature and pressure control by receiving data from...
Germany, Berlin
...Our new industrial process interface (PIF) allows for automated process monitoring, where the hardware of the PI thermal imaging cameras, along with all cable connections, and the free analysis software optris PIX Connect are continuously monitored during operation. Unique in the market is the control of the external computer in this monitoring process. Interfaces: 3 analog/alarm outputs, 2 analog inputs, 1 digital input, 3 alarm relays Isolation Voltage: 500 V ACRMS Additional: Separate fail-safe relay output...
... potentiometer. If the measured voltages are above the switching point, the output relay with 2 changeover contacts is activated, and the operating indicator (green LED) lights up. If one or more phase voltages drop below the switching point, the relay deactivates, and the operating indicator goes out. A constant state change is prevented by the introduced hysteresis, which fluctuates around the switching point of the measured voltage.
Germany, Darmstadt
...Monitoring relays for current, voltage, phase sequence, phase failure, phase asymmetry, power factor, active power, and motor temperature. Additionally, NO protection relays and relays for pump control.
France, Poissy
... non-metallic, it is possible to measure through them from the outside. Material to be measured: Dust, powder, or granules Operating principle: Microwave Process pressure: max. 20 bar Process temperature: up to +1000 °C Type of conveying: all Flow rates: no limit Pipe diameter/detection range: up to 1200 mm Output: Relay...
Germany, Bamberg
Wieland Electric is a medium-sized family-owned company in the electrical and electronics industry, headquartered in Bamberg. Our extensive product portfolio forms the basis for comprehensive services across many sectors. We provide extensive service for industry as well as innovative building and lighting technology. In the field of security technology, we include not only products but also train...
...%): 450 : 1 (2.2 mrad) Measurement points per line scanner: 1024 per line (2048 for CS212) Ambient temperature: -40...45 °C (no direct sunlight) Ambient temperature - position sensor: -25 ...230 ºC Alarm zones: 48 software, 3 hardware (PC independent) Kiln speed: Up to 10 rpm Tire ring management (LRM): Supports up to 6 tire rings Fan control: Up to 16 fans per module (48 total) Communication: Ethernet TCP/IP Analog outputs: 3 x 4 – 20 mA Alarm output: Relay, contacts: 30 V, 1 A Power supply: 24 VDC ± 25 %, 1 A...
Germany, Nürnberg
...Temperature Monitoring Relay RH41M / NTC Input / Marine Approval - Limit Switch for Temperature (NTC). Simple application; designed for harsh operating conditions. Switching limit adjustable via drum scale. Compact and robust design. Approvals: BV, DNV-GL Operating Voltage: 18...32 VDC Input Signal: Temperature, NTC Output Contact: Potential-free relay contact (normally open) Maximum Switching Power: max. 40 W (0.2 A at 220 VAC) Operating Temperature: -20...+70 °C Connection: DIN 46244 Flat Connector A6.3 x 0.8 Mounting: G-Rail TS32 or DIN Rail TS35...
Germany, Donauwörth
... ✓ Fuel gauge ✓ Approved to IEC/UL/CSA 61010-1 / -2-201 ✓ 3 years warranty The DC UPS UPSI-2406DP1 with included energy storage has been designed for DIN Rail applications. The robust housing protects electronic parts against coarse pollution. The µC-controlled DC-UPS is based on the proven UPSI-technology and features numerous protective and monitoring functions as well as an integrated reboot...
Switzerland, Wittenbach
... Detector AGS Relay preliminary alarm/alarm:below 2 A at 30 VDC or 250 VAC, SPDT Detector AGS Analog output signal:4 - 20 mA Sensor Material box:plastic (IP54) Sensor Gas entry:diffusion Sensor Measuring range:0 - 5 Vol. % CO2 (0 - 50.000 ppm) Sensor Accuracy:0.1 Vol. % CO 2 (+ - 100 ppm or + - 5%) Sensor Operating temperature:0 to +50 ° C Detector AGP Alarm settings:3 thresholds Detector AGP Alarm...
Germany, Hildesheim
... calibration and no drift effects compared to electrode measurement. No wear or regeneration of the sensor necessary. Separate connection cables for power supply, relay, and input contact. Status indication through four LEDs for threshold compliance, analysis status, device status, and upcoming service. Product Information LIMES Plus LED status indication language-neutral Initial value suppression to prevent false alarms Flush duration adjustable to the supply line length...
Germany, Bruchköbel
...Protection conductor monitoring for single-phase and three-phase networks Standard basis: DIN EN 50178 / VDE 0160:1998-04 The PECON+ is designed for the safe monitoring of the availability of the protective conductor system in AC and DC networks. The PECON+ measures the availability of the protective conductor and activates an internal relay when the protective conductor is present (operating...
Germany, Köln
... Detection Limit:ppb to ppt for most analytes Repeatability:RSD calculated Temperature:5 to 45 Ionization Source:Ni-63 2.4 mCi Sensitivity in Water:1; 0.5 ppb MTBE in water s/n >15:1 FTP:Configurable for automated data upload Storage:160 GB (minimum) hard drive Touch Screen:6.5 in. VGA color display with touch screen Wireless Connectivity:802.11 B/G Integration:I/O Relay Contacts USB for local...
Germany, Blumberg
...Monitoring relays are used to protect both people and machines, as well as to control electrical processes based on electrical or physical parameters. In certain applications, they are mandated by low-voltage regulations. METZ CONNECT offers a wide range of measurement and monitoring relays suitable for various applications: current monitors for universal use, phase monitors to protect against...
...TELE monitoring relays impress with their compact design, powerful technology, and extremely low energy consumption. TELE monitoring relays are available in various series: Series ENYA - modern technology for building services Series VEO - compact industrial design, extended wide-range power supply & temperature range Series GAMMA - monitoring solution for control cabinet and plant construction Series KAPPA - with 11-pin plug-in module...
...(Selectable) 2. Hardware Option1: 3 Input 5 Output or 3 Input 4 Output relay (Optional) 3. Hardware Option2: RS485+16bit Analog or 2 Input 4 Output 4. Hardware Option3: Modbus TCP or Ethernet/IP or Profinet (Hardware Option1,2,3 can be selected at the same time) 5. Bluetooth Communication ...
...The flow sensors for gaseous fluids provide a signal proportional to the mass flow rate of air. The devices are intuitively adjustable using a potentiometer and an LED display. The LDN 500 is particularly well-suited for reliably monitoring compressed air flow and other gases.
...Format 48 x 96 mm, portrait Two/three step, continuous controller Sensor monitoring Up to 5 outputs 1 Analogue input (universal) 1 Binary input 1 Relay output (closing contact) Self-optimization (autotuning) for exact PID control Manual/automatic mode Configurable limit monitoring (alarms) Setpoint switching Level/keyboard locking RS485 interface (Modbus RTU) Ramp and timer function Firing curve for ceramic furnaces Plug-in controller module Setup interface (USB Mini-B)...
Germany, Ettlingen
...Referencing to an empty cell or a reference liquid is available. The photometer uses an optical path length of 50 mm. Operation of the photometer is menu-controlled with a graphical display. Measuring data are shown on the display. They are also transferred to an analog and a digital interface. Two adjustable alarm thresholds are available for the system controller via relay contacts. The UV...
...Volume flow monitoring systems are used to monitor air flows. They contain a calorimetric sensor housed in a protective casing. Integrated features include evaluation electronics, output relays, adjustment potentiometers, and LEDs, as well as a time relay for start-up bypass. Volume flow monitoring systems are available in nominal diameters of 75-400 mm connection diameter. They can be supplied with flange and socket connection options. Standard materials available are PPs and PVC. Special materials available upon request. For more information, please visit our website or contact us directly.
Germany, Gräfelfing
...3-Phase Semiconductor Relays for DIN Rail Mounting SSR 3-phase, from 25-75 A, ready for installation including heat sink (with fan for 60/75 Amperes), IP20, optional monitoring, AC or DC control, switching 2 & 3 phases.
Switzerland, Würenlos
...The AKSA/GTEC series of transfer switches are designed for monitoring and controlling grid feed-in and emergency power feed-in. The emergency power switching and generator start occur fully automatically. The contacts are silver-plated, allowing for several thousand switching cycles without additional service. Three- and four-pole versions ensure a cost-effective solution for every application.
France, Rambouillet
...The ControlByWeb WebRelay™ offers a robust solution for remote relay control and digital input monitoring over any IP network. Versatile, it adapts to various industrial and commercial applications, featuring a user-friendly interface and advanced functionalities. Its password protection, reliability up to 12 amps, opto-isolated input, and flexible power options make it an essential tool for modern automation. Choose the WebRelay™ and experience the cutting edge of remote control technology.
...Regarding coupling protection for small power plants in the grid – parallel operation – generator protection or general measurement and monitoring tasks in the industrial sector, as well as monitoring of voltage drops and surges – compact electric develops customized technical solutions at the highest level. They are used by energy supply companies as well as small power plants and in industrial...
...Detect faults in motors and other equipment based on changes in current. For use in overcurrent or undercurrent mode. - Monitoring of AC or DC currents with a single relay - For use with commercially available CTs (secondary side CT: 0 to 1 A or 0 to 5 A) - Settings for setpoint, hysteresis, delay on activation lock, and operating time - Width of 17.5 mm for reduced space requirements in panels...
ufs.country_names.RU, Moscow
...The dry contact board (relay card) is used to provide the UPS peripheral monitoring interface. Contact signals can indicate the current status of the UPS. The appearance and pin numbering of the dry contact relay board may differ depending on the UPS model Article:CNRL003...
... contact with the performance of the latest semiconductor technology. The hybrid, low-arc switching system allows for multiple and safe disconnections of up to 2 megawatts – 2,000 A/1,000 V, even in overload situations. The device can withstand higher short-circuit currents of up to 5,000 A until the fast HV fuse triggers. This palm-sized device can switch 300 A up to 50,000 times with low arc and wear, and can carry the load continuously. An innovative self-monitoring feature immediately reports critical operating conditions to the control unit.
...Relay components for: Potential separation Voltage conversion Contact multiplication Load control...
ufs.country_names.RU, Zarechny
... 1.8 m Power Supply: 9…30 V Current Consumption: 0.035 A Detection Probability: 0.98 Temperature Range: -40 to +80º C Protection Class: IP-55 Alarm Output: Relay Contact Dimensions: 213x213x70 mm Weight: 2.4 kg...
... 7 and Syntel protocols (Lonworks) for monitoring addressable events. The devices come standard with a configurable 4-20 mA or 0-22 mA output (PLC), two configurable alarm relays, and two detector status LEDs.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play