Germany, Ilmenau-Unterpörlitz
... impacts. The measurement output is digital via an I²C interface, with the address being customer-specific. Thanks to the bus capability of the interface, combining multiple sensors within a system is easily achievable. Measurement range:: 0...80% rH, 80 - 100% rH (short-term); -40..+100°C Accuracy:: +/- 1.8% rH in the range of 10..80% rH; +/- 0.2% rH in the range of 0..10% rH; +/- 0.2° C in the range of 0..60°C Operating pressure:: max. 150 bar...
Switzerland, Ebnat-Kappel
... precise humidity transmitters. Further advantages of the HYT 939 digital humidity module include: — Calibrated and temperature compensated — Excellent humidity/temperature accuracy and stability — High chemical resistance — I2C protocol (address 0x28 or alternative address) — Wide humidity and temperature range (0 % RH to 100 % RH and -40 °C to +125 °C) — Very low drift — Very stable at high...
France, Bordeaux
...Innolog ™ SU is a single-use temperature logger equipped with a digital sensor. Each device has been factory validated and comes with a unique traceability certificate. It is protected by a waterproof protective packaging. Each logger receives 2 detachable labels with a unique barcode to ensure unambiguous identification and traceability of the recordings.
Germany, Ettlingen
...The PLC.D sensors are ready-to-install UV sensors with digital output. This enables reliable and repeatable irradiance measurements in UV systems. Due to the compact design and the eight spectral ranges, the sensors can be used for a wide range of applications, e.g. in packaging facilities sterilisation surface activation systems UV curing systems ageing tests and many other applications With the...
...The sensor module µCAN.1.ti-SENSOR can be joined with any sensor and is designed to acquire an analogue temperature signal. It can be integrated directly in the sensor head (18 mm in diameter). Sensor tolerances can be adjusted with the module already built in. The sensor signal is linearized and monitored directly in the hardware.Temperature Thermo type J, K, L Temperature Pt100, Pt1000 (2-wire...
Germany, Buchenbach
SIKO today stands for five decades of experience in various measurement tasks: length measurement technology, angle measurement technology, rotational speed measurement technology, as well as measuring inclination or speed. Building on this core competence, SIKO develops and produces pioneering measuring devices and positioning systems for automation processes. The highest demands of our customers...
Germany, Otterfing
...LG20 - Magnescale ® Number of axes: 1, 2, 3 Version: Standard counter Digital input for sensor: SJ300, SJ700, GBER, PL20C, DK measuring probe Sensor power supply: yes Digit: 7 Selectable resolution: 0.1, 0.5, 1, 2, 5, 10, 20, 25, 50, 100 µm...
Belgium, Rumst
... gauge sensor technology, this digital kitchen scale provides accurate measurements with a capacity of up to 5000g and an accuracy of 1g. Its large LCD display and intuitive interface make it easy to read and operate, while the counting function allows for precise portion control and ingredient measurement. Additionally, the scale features a variety of units for flexible usage, including grams...
Germany, Mainz
... ceramic housing provide the pressure sensor with high mechanical stability. The pressure sensors in this series are unidirectionally media-protected through back-side coating* and have a digital signal resolution of 14 bits. They are available in the following versions.
Türkiye, Istanbul
...60UT ProD is a mobile style ultrasonic cleaning device. It can take 3 54cm washing baskets. It can be easily moved thanks to its wheeled structure. It heats the liquid from the inside with its 2 internal heaters, saving energy. It is equipped with a liquid level sensor, preventing dry operation due to error. It is controlled with a digital panel. It is your greatest assistant in cleaning...
Germany, Thierstein
... sewage as well as for viscous and pasty media. Basic element is a robust and high overpressure capable capacitive ceramic sensor. Features — Nominal pressure: from 0 ... 40 cmH2O up to 0 ... 200 mH2O — accuracy: 0.35 % (opt. 0.25 %) FSO — output signal: RS485 with Modbus RTU protocol — diameter 39.5 mm — excellent long term stability — especially for sewage, viscous and pasty media Optional features: — diaphragm ceramics Al2O3 99,9% Housing material:Stainless steel Communication:digital Sensor:ceramic-capacitive...
... function integrated as standard allows for direct evaluation of measurements almost in real-time; these can be processed further by a higher-level controller. A rather more comprehensive acquisition method is also integrated into the system. Type of sensor:Incremental position sensor Interfaces:RS232 Indicator:± 999 999 Supply voltage:10.8 ... 26.4 VDC, max. 12 VA Measurement channels:2...
Germany, Hamburg
...The PR 6221 series load cells have been specifically designed for use in truck scales. Exceptional precision and long product lifespan reduce service and calibration costs, helping to minimize downtime. When combined with the Connexx® converter, the PR 6221 sensor becomes a digital solution. - Exceptional reliability thanks to German quality - Precise measurement results due to the special...
Switzerland, Muttenz
...The mass flow meters of the red-y compact 2 series are characterized by powerful technology, intelligent features, and innovative design. The new generation of flow meters offers users high flexibility in application: compact design, battery operation, and a touch display with backlighting. Touch Technology: Independent battery operation USB Interface: High accuracy & dynamics Enhanced alarm functions: MEMS sensor technology...
Germany, Donaueschingen
...The B+B measuring transducer module Pt1000 with current output 4-20mA, is an accurate reliable digital measuring transducer in a miniaturised PCB design with modern ASIC technology - digitally calibrated for connecting Pt1000 sensors. Name:Measuring transducer module Temperature measuring range:0...+300 °C Sensor:Platinum sensor Pt1000 , resistance characteristic DIN/IEC 60751 Measuring current...
Spain, Barakaldo
...M1 Defrosts due to compressor stop Cooling / Heating Compact and vertical High clarity blue display Decimal Point 1 Sensor input 1 Control / alarm relay ON / OFF Alarm buzzer 120×74 (x30) mm 230…110 V Inputs / Ranges: PTC = -50.0/+150.0 ºC NTC = -50.0/+110.0 ºC Accessories: KEY USB...
... Analog output:± 0.25 % FS Drift vs Ambiant Temperature Analog output:± 0.25 % FS Sensitivity:Linear (See calibration table) mV/°C Sampling frequency:5 Hz Supply Voltage:5–16 V or 12–33 V Supply Current:3 mA Output Voltage:0–5 V or 0–10 V Output Impedance:47 Ω Digital output:ASCII @ 5hz, 9600 Bauds Calibrator:Fluke 714 Dimension “P” type:35 x 20 x 10 mm Material “P” type:Plastic Dimension “A” type:32.5 x 19 x 10 mm Material “A” type:Aluminium Weight:15 g Protection:IP53 Vibration test:20Gpp5’ Shock:500 G Operating Temp:-40 to +125 °C Storage Temp:-40 to +125 °C...
...Design: Ergonomic, service and drip tray are integrated with the machine body. Control System: Smart Plus control panel (programming each day separately - electricity / on / off / temperature control / wate level control / maintenance period determination / working mode / real time clock / day no. Temperature Control : Digital temperature sensor Temperature Display: Digital display Water System...
Germany, Mülheim
... transmitters for float-based level measurement are also available, as well as cable pull sensors. Position information can be transmitted with high precision and dynamically over measurement lengths of up to 40 meters via digital and analog interfaces to the higher-level control system.
...The Thermalert TX infrared temperature sensors are available with remote addressability, easily installed in multidrop configurations. TX Series Smart Sensors communicate over a simple loop-powered 2-wire cable using the HART (Highway Addressable Remote Transducer) protocol. This signal combines industry-standard 4-20 mA output with simultaneous digital communications. They include Raytek...
Germany, Heinsberg
... (distance/measurement surface ratio): 75:1 Minimum diameter of measurement surface: 18 mm @ 1,350 mm Measurement range contact sensor: 50 °C ... +300 °C Accuracy: ±1.5 % ± 3 °C Reproducibility: ± 1.5 % Response time: < 150 ms Spectral resolution: 8 ~ 14 µm Laser class 2 (II), wavelength: 630 ~ 670 nm, power: <1 mW Monochrome backlit liquid crystal display Operating conditions: 0 °C - 50 °C, 10 % - 90 % r.h. Storage conditions: -10 °C - 60 °C, < 80 % r.h. (without condensation) Power supply (internal): 9 V IEC 6LR61 Technology: infrared Display: digital Configuration: portable...
Türkiye, Bursa
... control Separate power and control power supply Fast and accurate positioning Incremental and absolute encoder Nominal voltage:12 V/DC IP protection class:IP67 Work Temparature:15OC, +40OC Length x Width x Depth:164 x 94 x 32 CM Art. No.:0612034U P. Qt.:1 Auto Range:No Digital Sensor Reduction:DNR L.A. Length:20/40/80 Payment Module:Coin, token...
France, Poissy
... monitoring of emissions (for up to 32 sensors) • full colour, icondriven menu and display • two independent alarm set points • relative dust reading on clear scale 0100% • dust 'overrange' icon • security setting • digital signal processing • field upgradeable...
Germany, Köln
... carriage Guide: DryLin® W DryLin® W - Digital measuring system DryLin® measuring system Ready-to-fit measuring device for external signal output Resolution 0,1 mm Accuracy +/- 0,025 Small sensor with integrated unit drylin® WKMEX measuring system with external output...
... protective housing Protection class: IP65 (NEMA4) Spectral range: 1.0 μm, 1.6 μm Accuracy: From ±0.5 %/ ±2 °C Resolution: 0.1 °C Response time: 10 ms, 20 ms (95 %) Power supply: 20 to 48 VDC, 500 mA or Power over Ethernet (PoE) Digital outputs: Ethernet, Profinet Serial interface: RS485 Analog output: 0/4 – 20 mA Alarm output: Relay, 48 V, 300 mA...
Germany, Paderborn
...Used to correct the tension factor of a drive, thus assisting the user in maintaining optimal belt tension. This device operates on the principle of frequency measurement. Features - Non-contact measurement with repeatability - Wide measurement range from 10 Hz to 600 Hz - High accuracy - Evaluation of measurement result quality - Suppression of background noise - Universal measuring head for comfortable measurement - Removable measuring sensor for tight spaces...
France, Chateaufort
...Oxygen trace detector for inerting. Standalone device with sampling pump. Digital display. Zero calibration via function key. Monochrome display with 2 lines. Option to sample from a 60 bar network. Display of sensor and pump faults. Battery life: 11 hours in continuous mode, 15 hours in standby mode. Transport case included. Delivered with 3 m of food-grade tubing. Float sampler available as an...
Germany, Ortenburg
...The RS422/USB converts digital signals from up to 4 optical sensors into a USB data packet. The new converter has 4 trigger inputs and a trigger output for connecting additional converters.The data are output via an USB interface. The converter as well as the connected sensor are parametrisable by software.
France, Fontaines Les Gres
...Housing plastic. Screen LCD display. Version Position indicators with integrated battery compartment. Plugin sensor. Lowpower LCD with decimal and fraction inch function. Note Digital, mainsindependent measurement display for playfree position detection. The system is often used in industry and trade for measuring tasks on length and angle stops (on panel saws, sheet punches, press breaks...