Germany, Porta Westfalica
...foot switch model F1 model F1 UN * without protection * with safety protection * safety lock, manual release * IP 65 Function: control Type: 1 pedal, 2 pedals, 3 pedals Other features: with protection, reinforced...
Germany, Heiligenstadt I.ofr.
... abrasion-resistant, heat, UV, and solvent-resistant power label the output voltage is indicated by a green LED Input voltage: AC 220/230/240 V or AC 380/400/420 V Switching group: Ii0 with shield winding Output voltage: SELV DC 24 V according to EN 61131-2 Protection class: IP 00 Ambient temperature: max. 60°C Frequency: 50-60Hz Power range: 72 W - 192 W Residual ripple: < 5% Emissions: EN 61000-6 -3/-4, (Class B) Immunity: EN 61000-6 -1/-2 Protection classes: I...
Germany, Darmstadt
...1- and 3-phase switch-mode power supplies for DIN rail mounting and 1-phase flat designs for installation in sub-distributors Switch-mode power supplies for sub-distributor installation, switch-mode power supplies for DIN rail mounting, 1-phase, switch-mode power supplies for DIN rail mounting, 3-phase, switch-mode power supplies for DIN rail mounting, 2-phase, redundancy modules for switch-mode power supplies, battery chargers...
France, Guenange
...Metal housing with DIN rail mounting - Input voltage of 90 to 264 Vac single-phase with PFC and 115/230 Vac single-phase with internal switch (depending on the model) - Possible supply in 230 and 400 Vac three-phase - Frequency of 47 to 63Hz - Operating voltage: 12, 24, 48 or 110Vdc +/-5% - Voltage adjustable via external potentiometer - Output regulation: ± 2 % - Residual ripple: <200 mV...
France, Fontaines Les Gres
...2-phase high-torque stepper motor in NEMA 17, NEMA 23 and NEMA 34 sizes with flat-milled shaft (D-shaft). 1.8ׄ° increment angle (full increment) with integrated positioning control. Note: Stepper motor with integrated positioning control. It forms a convenient unit consisting of stepper motor and intelligent controller. Reference travel is possible on a block with reduced electric current without...
Germany, Wilkau-Haßlau
...Electronic Reactive Power Controller BR 7000 Three-phase measurement and control Reactive power controller and network measuring device LCD full graphics 128 x 64 pixels Dimensions: 144 x 144 x 50 mm Inputs: Operating voltage: 110...440V~ 50/60Hz 3 x Measuring voltage: 30...440V~ (L-N) 50...690V~ (L-L) 3 x Measuring current: X:1A / X:5A 1 x external input Outputs: 3 x 5 relay switching outputs for capacitors 3 relay outputs for notifications, alarms, fans 2 interfaces RS485 - Modbus RTU (RJ45)...
Germany, Oestrich-Winkel
... housing - Peak load 150% - Tested according to UL 508 for industrial system controls - Active DC Power OK signal output - EN 61000-6-2 (EN 50082-2) - Power consumption in no-load operation: < 0.75 W - Wide input range AC 88 V to 264 V, DC 127 V to 370 V - Permissible ambient temperature: -40 °C to 50 °C Item No: 27893 Manufacturer No: NDR-240-24 Number of output voltages: 1 - Single Output connection: Screw terminal Input connection: Screw terminal Design: DIN rail Protection class: Protection class I...
... required. • Form factor F < 1.05, resulting in low motor heating and high torque reserves. • Overload capacity up to 200% peak current for a maximum of 1 second. • Stall protection with overload shutdown. Accessories: • Module carrier for 35mm mounting rail • Module carrier for screw fastening • Setpoint potentiometer 1 gang or 10 gang Dimensions: • PCB version: 160 × 100 × 40 mm (L × W × H) • Connection: 16-pole pluggable screw terminal block Armature voltage: 0-210V DC Description: 1Q GS1/xx-294 Input voltage: 230V AC Motor current: 2/4 A...
...-in electronics! Connection: 1.20 m long connection cable with Schuko plug. Other plug connections, such as Swiss type, are available. Output: 0 - 228 V torque-stable, max. 1200 VA On/Off switch: Illuminated rocker switch, 2-pole switching Installations: Rotary potentiometer with scale 0 - 10 for speed adjustment and additionally externally adjustable trimmer for fine-tuning. Input: 230 V~ +/- 10...
... potentiometer. If the measured voltages are above the switching point, the output relay with 2 changeover contacts is activated, and the operating indicator (green LED) lights up. If one or more phase voltages drop below the switching point, the relay deactivates, and the operating indicator goes out. A constant state change is prevented by the introduced hysteresis, which fluctuates around the switching point of the measured voltage.
Germany, Gräfelfing
...3-Phase Semiconductor Relays for DIN Rail Mounting SSR 3-phase, from 25-75 A, ready for installation including heat sink (with fan for 60/75 Amperes), IP20, optional monitoring, AC or DC control, switching 2 & 3 phases.
Spain, Alcalá De Guadaira
...Permanent surge protector caused by increases in network voltage, and transient overvoltages due to lightning strikes or network switching, in three-phase installations. Composed of IGA + 3 triggering coils + Vigivolt V3T. SPECIFICATIONSGeneral Values Operating Voltage240 VAC Frequency50-60 Hz Maximum Terminal Section25 mm² Dimensions (width x height x depth) mm162 x 90 x 71 Weight1022 g...
Switzerland, Bad Ragaz
...Extremely powerful 6-pole relay with forced-guided contacts according to EN 50205 for switching loads up to 16 A. Crown contacts for high switching reliability on the 2 feedback contacts and 4 power contacts up to 16 A and 60 A peak currents. For the highest loads in 3-phase applications and DC loads.
Germany, Gröbenzell
...Stepper Motor Driver for 2-Phase Stepper Motor 5 A(PEAK) 24-70 V - sin/cos via - The APS module from phytron is a compact (only 40 x 60 mm!) high-performance driver for operating stepper motors up to 5 A(PEAK) at 24 - 70 V(DC) for a wave power of up to 250 W. With up to 70 V (DC), the APS is also suitable for high speeds, highly inductive, and high-resolution stepper motors. Control via pulse...