Germany, Nettetal
... outlet water temperature down to 0 °C. The Taurus Tech operates with an ambient temperature of up to 47 °C in cooling mode. The chillers, reversible heat pumps, and condenser-compressor units of the Taurus Tech series are designed for outdoor installation (protection class IP54). Construction and manufacturing of the Taurus Tech series are carried out in accordance with the quality assurance guidelines of ISO 9001. Cooling capacities from 71 to 152 kW, heating capacities from 78 to 150 kW.
Türkiye, Maltepe
...According to your requirements we supply rack units with a wide selection of optional components, electrically pre wired or with switch cabinet. We also offer the ideal control system adapted to each individual application. This system mostly using for more than 3 rooms cold storage plant. Technical Specification It has semi hermetic, scroll or screw type compressor. Be manufactured with air cooled or water cooled condenser. All equipment are delivered together with control instruments as being ready to assembly.
Germany, Meinerzhagen
...AIR- AND WATER COOLED COLD WATER UNITS gwk chillers in the sklc series are air-cooled compact cold water units with integrated condenser gwk chillers in the skw series are water-cooled compact cold water units cooled with external cooling water These chillers are equipped with screw condensers; the power regulation of the capacity to be dissipated is continuous. Water-cooled cold water...
United Kingdom, Cannock
... electrical connections, no neutral cable required. Quick and easy to install. Can be used with site condenser water or supplied with stand alone cooling tower. Environmentally friendly. COOLING CAPACITY:1400 kW (@ LWT 6°C, Ambient 30°C) POWER SUPPLY:400V 3p 50 Hz HEIGHT (M):2.59 LENGTH (M):6.06 WIDTH (M):2.43 WEIGHT (KG):12565...
Germany, Murrhardt
...Water Cooling Units 4 - 122 kW Portable water cooling units 4 - 135 kW comply with the new ECO design directive air-cooled version with microchannel condenser up to max. 46°C ambient temperature (optionally also water-cooled) many options already standard, such as: -closed tank (up to max. 2.5 bar) -air intake filter -outdoor installation (condensation control, crankcase heater, etc.) Many options available: EC brushless EC fans 0-100% speed controlled and ductable unit without tank as a flow cooler manual filling various interfaces UL - 480V/60Hz version etc.
...Chiller Systems: High-performance cooling units that provide precise temperature control for various applications.
Lithuania, Vilnius
...Wide range capacity liquid cooled condensing units, designed for commercial and industrial applications with the cooling capacity from10 kW to 40 kW. These units work on a principle of the heat rejection loop, where condenser heat is dissipated to the environment via water. Rejected heat can be used for additional needs in the same building, which gives these facilities additional economic...
Germany, Dorsten
...Environmentally friendly with an ozone depletion factor of zero. Low noise levels for use in noise-sensitive environments. Low operating costs due to energy-efficient compressor units. Easy-to-read and adjustable control panel. Protection devices for the condenser fan provide protection against accidental damage on-site. "Night noise reduction" with high efficiency or options for quiet operation. COOLING...
Italy, Milano
... 10-foot container ISO lift equipment. COOLING CAPACITY: 165 kW (LWT @ -25 °C, Condenser water 6 °C) MIN. OUTLET LIQUID TEMP. (°C): -40 °C POWER SUPPLY: 400V 3p 50 Hz HEIGHT (M): 2.59 LENGTH (M): 3.05 WIDTH (M): 2.44 WEIGHT (KG): 4293...
France, Saint Ouen L'aumône
... water and air ejector. 115 m3/h of gas containing solvents at 10 mBar abs. Cooling with glycol water at 5°C. ECOVAC We have developed a range of pollution-free liquid ring pumping units; the closed circuit jointly ensures the cooling of the liquid ring and vent gases, thus reducing the emissions of non-condensable vapors into the atmosphere (VOCs). Principle The aspirated gases and vapors are...
Belgium, Mornimont
... before heating coil: 2.8 kW/35°C Water heating coil 70 kW/50°C 30°C before heating coil: 9.2 kW/46°C Water-cooled condenser: 3.2 kW at a water temperature of 28°C/HP 40°C Compressor COP: 4.2 Power: 13.3 A Maximum absorption power: 2900 W Power supply: 3x230V Dimensions HxWxL (mm): 1595x1750x780 Duct dimensions (mm): 300x470 Weight: 389 kg Available for rent: No...
Germany, Donzdorf
... with an external dry cooler or an external air condenser, allows for cold water production with high energy-saving potential at low ambient air temperatures. The devices are designed to operate with the refrigerant R407C (version K). The units are supplied with nitrogen filling. Operation between +20 °C and +37 °C air intake.
KURUMAN Industrial Cooling Systems sector has been established for many years to eliminate the deficit of cooling, air conditioning, ventilation and heating devices. Air Cooled Condenser Cold Water Producer Groups, Natural Cooling and Adiabatic Cooling Integrated Cold Water Producer Groups, Water Cooled Condenser Cold Water Producer Groups, Marine Type Cold Water Producer Groups, Package Type Air...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play