Italy, Guarene
...MS80 - MANUAL GLUE GUN WITH GRANULAR HOT MELTS The MS 80 glue gun works with granular hot melts without compressed air. Simply connect them to the socket – ready. Use the thermostatic controls to set the requested temperature between 20°C and 200°C and you always work with the optimum glue temperature. Pull the trigger to apply the melted granulate. The MS 80 has proven successful in practice...
Germany, Hamburg
...Error-proofing (PokaYoke) torque screwdriver with limit switch output to eliminate missed tightening. Ideal for assembly processes with torque monitoring. After reaching the set torque, the limit switch transmits a trigger signal. This can be picked up by means of a PLC, for example. At the same time, the slip clutch is activated, making over-torque impossible. Series RTDLS are adjustable...
... intelligent auto-configuration, even semi-skilled staff can set up the equipment safely and quickly. "Card & Go" is the smart system that uses master, tool and PLC smart cards to make equipment settings, inhibit unauthorized changes and to trigger actions in sequence with the production process. The ForceMaster 9110 has been developed specifically for monitoring manual lever presses. Simple manual...
Germany, Neumünster
... brushless DC (BLDC) motor. Ergonomy and comfort: Quick-release mechanism: No more than one open-jaw wrench for maintenance! Individual return mode setting When using manual return mode, the trigger has to remain pressed until the rivet is sheared. When the trigger is released, the tool moves back to the front starting position. In addition Rivdom eBZ tools offer an automatic return mode. L...
... Storage Capacity: 4 MB (up to 10 runs, 8 thermocouples, 60 min duration, 5 s interval) Measurement Interval: 0.5 s to 50 min Multiple Runs: Logger stores up to 10 measurement runs Cold Junction Compensation: Yes Data Acquisition: Plug and Go; Temperature Trigger Battery Type: Rechargeable NiMH Max. Duration in Process: Up to 24 hours at 100 °C, up to 75 min at 600 °C (model dependent)...
France, Rives-En-Seine
... will find a Hornet handle, a Hornet lance with a power of 90 kW, along with a Wizz lance with a power of 100 kW. There are also 10 meters of hose 963/10, a fixed regulator of 4 bar 684, and a quick connection device. To complete this pack, a spare piezo trigger has also been added to this case. Power: 100 kW, 90 kW...
Netherlands, Assen
...SAMOA mechanical, preset control valves enable the automatic filling of large sumps, engines, and other lubricant reservoirs. For automatic operation, set the dial to the required amount and activate the trigger for automatic locking. The valve delivers exactly the needed volume and then shuts off. · Extensively and rigorously tested in practice. Reliable performance. · No calibration required...
France, Saint-Germain-En-Laye
... output in series sheets. Features of the Inline 500 Compact Binder for notebooks and calendars: Maximum length of bound side: 500 mm. Minimum/maximum length of unbound side: 100 / 500 mm. Binding diameters achievable: from 5.5 to 25.4 mm (jaw set required for each diameter) in 2:1 or 3:1 pitch. Automatic distributor for straight rods KAS 300 for shaping calendar hooks (automatic insertion into the binding) optional (requires compressed air). Perforation capacity: up to 4 mm thickness Usable binding diameters: from Ø 5.5 to 25.4 mm Motor power: 2 kW Electrical supply: three-phase 400 V / 50 Hz...
... industrial gases including hydrocarbons and corrosives like ammonia. Every Flow-Trigger™ comes complete with an orifice calibration curve and is preset to trigger at the desired set point based on the provided inlet gas specifications. The switch is field adjustable (+/- 40% of initial flow set point) after installation so that it can be fine tuned to meet specific application requirements. The Flow-Trigger™ is designed to be easily installed directly into a gas pipeline and comes complete with the required inlet and outlet pipe to maintain calibration accuracy.
...The TM 1/9 Ex is a thermal detector and features two different triggering criteria that operate in parallel. It not only responds to exceeding a set temperature threshold but also alarms at a typical temperature rise associated with fire. Specifications Supply Voltage: 13 V to 30 V DC Current Consumption: min. 3 mA to max. 30 mA Temperature Switching Point: Classes...
Germany, Mindelheim
...Finally more mobility and less tension With the help of the fascia roller set, you can release stuck fascia and treat painful trigger points. Feel how you become more agile and mobile every day.
Türkiye, Arsuz / Hatay
The company is a reliable automotive spare parts supplier that focuses on customer satisfaction, has a deep understanding of its industry, and effectively analyzes customer expectations to meet them quickly, with quality, and at the best price. With a commitment to continuity and an experienced team, our company, which has started its commercial activities in the wholesale and retail spare parts s...
... includes, for example, drills, mixers, electric planers, or electric saws, as used in industry, households, or hobbies. The speed can be adjusted continuously using the potentiometer. If the motor current increases due to higher load, the torque is automatically adjusted. The strength of the adjustment can be specifically set for each motor type using an externally accessible trimmer. Not suitable...
Germany, Eichenzell
... of an asynchronous generator is sufficient, as amplitudes starting from 0.7 V can be measured. Due to the measurement principle, no sensor is required. The measuring transducer of the WA-DR8/G outputs the speed at the output as a standard signal of 2-10 V DC. Monitoring for under- and over-speed Additionally, the WA-DR8/G monitors the measurement for under- and over-speed. For signaling, there is one relay with a changeover contact available, and the status is also displayed via LEDs on the device. The trigger limits are set via coding switches.
France, Canejan
... is very simple, and the built-in level will allow you to set it up in just a few minutes! It comes with: 1 x 9V battery (4 years of standby time) included in the unit, 1 manual in French, and 2 reset keys for the manual trigger. The PPMS radio alarm is activated by pressing the integrated manual trigger. Resetting the manual trigger using the provided key stops the alarm. This PPMS radio alarm is manufactured in France, is of very high quality, NF marked, and produced by one of the leading French alarm manufacturers...
Germany, Berlin
...For the start of our book production, we have set great store, even with a run 1 the book block exactly in the envelope. For this we have acquired an English grooving machine, which can groove us the envelope before the book block is hung. The groove lines are set according to the page number and size of the book. They are then engraved in the envelope. The cover thus becomes something like a...
France, Saint Ouen L'aumone
... allowing the use of 1/4" sockets according to DIN 3124 Trigger precision: tolerance +/- 6% of the selected value Compliant with DIN EN ISO 6789 with equivalence in national standards Precision coupling with ball circulation for controlled tightening in both directions Once the set value is reached, the precision mechanism slips in a perfectly sensitive manner. Automatic return to the initial position...
... barriers operate on 220V AC, with an internal voltage of 12V or 24V DC. A single trigger is sufficient to open the barrier. After that, it automatically opens thanks to the barrier motor. After a set period, it automatically closes and locks. If desired, the closing process can also be controlled with a button. In case of a power outage, the barrier switches to a free position and can be opened with a light push.
... as the installation of refrigerant detectors, must be implemented. The MVR-300 features acoustic and optical alarms. The device communicates with building technology via Modbus, and two integrated relays can be used to close valves or trigger alarms. The MVR-300 fits into standard flush-mounted boxes, and with the help of the decorative cover, the device is unobtrusive in the room. Complex maintenance is not required, as calibrated sensors can be installed with minimal effort in addition to simple on-site calibration. Versions are available for R410a, R407c, R404a, R32.
United Kingdom, Birmingham
... because of a fusible link which is set to trigger at It is a legal requirement to have these dampers tested at a minimum once every two years. Failure to do so can result in a fine, prison sentence and closure of business premises until rectified. AJS offer this essential fire safety service of a full fire & smoke damper testing and certifications with nationwide coverage. All test are carried out by fully qualified and trained technicians. Testing will include: Identify and locate each fire damper Retrofit access doors if any of these are inaccessible Carry out fire damper test...
Belgium, Auvelais (sambreville)
... efficiency and significantly reduces overheating. The high-performance charger determines an individual charging trajectory based on the battery's condition, ensuring a full charge in just 22 minutes and allowing continuous work with two batteries. Variable speed trigger and pre-selection of two maximum speeds enable even quieter operation while increasing battery life during light tasks. Anti...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play