Germany, Ilmenau-Unterpörlitz
...The ILMcom USB interface is used to connect an RS485 sensor bus to a PC with a USB interface. For more information, please contact us by phone or via the contact form on our website. Connection of: RS 485 sensor bus...
Germany, Karlsbad
...The Interface Converter is the perfect solution to integrate generators interface easily and quickly. It ensures compatibility with PROFINET, PROFIBUS, EtherCat, and ModBus TCP systems and is suitable for generators with a RS-485 interface.
... MB  Interfaces:2 x Ethernet 10/100/1000 MBit, 1 x RS-232, 1 x RS-485 galvanically isolated, 1 x CAN, 1 x CAN galvan Field bus interfaces:2 x CANopen, Modbus RTU, Modbus TCP, EtherCAT, OPC UA  Status indication:Power LED in the front, 4 x status on the back  Housing material:Aluminium with seamless film cover  Dimensions (W x H x D):320 x 265 x 54 mm  Status indication:Power LED in the front, 4 x status on the back ...
Germany, Hamburg
...Stainless steel indicators for simple weighing tasks and standard applications in two different versions. Maximum reading accuracy: 15,000 d, Protection class: IP65. LCD display 20 mm, 14-segment, backlit Integrated A/D converter for connecting analog platforms Material: Stainless steel type 304 AISI Optional RS-232, RS-485, RS-422, 4-20 mA, digital I/O...
Estonia, Tallinn
...Programmable stepper motor controller SMSD‑4.2RS is a modified and updated version of previous old models SMSD‑4.2RS-232 and SMSD‑4.2RS‑485. SMSD‑4.2RS provides both communication interfaces RS‑232 and RS485. Update frame is designed to be mounted on a standard DIN rail. Programmable controller SMSD‑4.2RS is intended for control of step motors with phase current up 4.2 A. The controller allows...
... (optional) — RS232 or RS485 (optional) — Analog or DCB output (optional) — Measurement accuracy < 0.1% — Scaled representation possible using the course procedure or by directly entering sensor data — Convenient configuration and evaluation software DigiVision Physical quantity: process, torque, pressure, force Dial type: digital, analog, LED Type: panel-mounted, tabletop Applications: for strain gauge bridges, for sensors Other features: RS-232, RS-485, high precision Additional features: analog output...
Germany, Schwerin
... and RS-485 with 9600 or 38400 Baud; CAN with 100 and 125 kBaud Protocol: standard commands of syringe pumps OEM Communication (OC) protocol and Data Terminal (DT) protocol Addressing: max. 15 devices with RS-485 Bus ("daisy-chaining"); max. 15 devices with CAN-Bus Inputs and outputs: 2 additional digital inputs with TTL Level; 3 additional outputs with TTL level Fluid connection: 1/4"-28 UNF...
... • Galvanically isolated analog outputs • Simplified installation: 2-Wire Sensor or RS-485 Communication • Compact and robust stainless steel housing • Excellent ambient temperature up to 85 °C • Air or water cooling housings for high ambient temperatures up to 175 °C • Cooling jackets for extreme ambient temperatures up to 315 °C • Air purges for dusty environments • Software for remote configuration...
Germany, Ettlingen
... integrated 24-bit ADCs, the PLC.D sensors close the gap between industrial manufacturing and high-precision laboratory equipment. Measurements can be carried out in a simple yet safe way. RS-485 and USB are available as optional connections for this purpose. The data evaluation takes place directly in the PLC.D sensors, the measured values are protected against transmission errors by a CRC-16 check sums. Operation voltage:24 V (RS-485 / RS-232) Dimensions:80 x 40 x 20 mm Weight:150 g Connector:Built-in plug, M8, 8-pin Response time, max:200 ms...
...["— RS 485 interface for internal Brabender fieldbus","— Application software for DDW (Dosing Differential Scales), DBW (Dosing Belt Scale) or Coriolis Flow Meters","— Internal fieldbus connection is pluggable","— Can be controlled via OP1, OP6, and OP16"]...
Germany, Bruchköbel
... coupling Optional fieldbus (Profibus, CANOpen…) Standard Modbus (RS 485) Numerous protection functions System accessories Easy maintenance (replaceable fan) Flexible expansion with additional cards Detachable keypad RoHS compliant CE, cUL certification marks Now also available as a cold-plate version! (Without heat sink)...
... x 78mm. PCB dimensions (L x W): 140 x 80mm. Type of connection: RS-485 Star. Cost reduction in installation with maximum efficiency. LED status indicator for power, serial ports, and network. 4 RS-485 serial ports from one RS-485 network. Case dimensions (L x W x D): 258 x 207 x 78mm PCB dimensions (L x W): 140 x 80mm...
Switzerland, Reinach Bl
...The WirelessHART Fieldgate SWG70 from Endress+Hauser serves as an interface between the WirelessHART network and a system that uses Ethernet or RS-485 as the bit transmission layer. The Fieldgate is designed for installation in explosion-hazard areas of Zone 2. Depending on the application requirements, the antenna can be mounted directly on the device or remotely.
Germany, Villingen-Schwenningen
...VA 500 - Flow Meter with Latest Evaluation Electronics The newly developed evaluation electronics records all measurement values digitally, unlike the bridge circuits typically used so far. This results in better accuracy even with large measurement ranges up to 1:1000. Advantages of the VA 500 Flow Meter: — RS 485 interface, Modbus-RTU standard — Option for integrated display for m³/h and m...
Netherlands, Capelle Aan Den Ijssel
... - Rich I/O interfaces including: RS-232/422/485 (optional), RJ45 Ethernet, USB, HDMI - High-capacity dual hot-swappable battery design - Integrated 1D/2D barcode reader, NFC, RFID, fingerprint reader - Enhanced security with Windows Hello authentication through fingerprint and front camera - Connectivity options include Wi-Fi 6E, 5G/4G, Bluetooth 5.3, and GNSS - IP66 and MIL-STD-810H certified...
Netherlands, Eindhoven
...Aluminum front panel with IP65 compliant 15.6'' TFT, Optimum resolution 1920×1080, Projected capacitive touch screen Support Intel® Core™ i3-1115G4 and i5-1135G7 2x Gigabit Ethernet ports, 2 X RS-232 (RS-485 optional) port with surge protection Wide voltage power supply: DC12~24V WIFI 6, 1 x Mini-PCIe slot, expandable 3G/4G Fanless design, VESA Mount, Panel Mount I/O: HDMI / 2GLAN / 4USB / 2COM / DC IN...
Türkiye, Istanbul
BİRİKİM KABLO® was founded in 2012 with the aim to serve the cable industry with unconditional customer satisfaction and competitive price strategy. With modern machinery and an expert technical team, the low voltage cables production is made in the 5,000 m² factory in Istanbul. From the founders to the management and sales force, every employee of BİRİKİM KABLO® has an experience in the cable ind...
ufs.country_names.RU, Zarechny
... smartphone (OC Android) via Bluetooth or USB on-site; -by computer connected via Ethernet; -remotely from the security post via RS-485. The sensors FM-60-C (Curtain) have 5 frequency letters. Operational frequency:9,375 GHz Range:5…60 m Detection width:4 m Detection height (in free space):25 m Supply Voltage:10...30 V Current consumption:0,04 A at 24 V Detection probability:0.98 Operational temperature:minus 50...+80 °C Protection Level:IP-55 Alarm output:Relay contacts Interfaces:RS-485, USB, Bluetooth or Ethernet (upon request) Dimensions:211x134x78 mm Weight:1,5 kg...
Austria, Olbendorf
...4-20mA, RS 485 Modbus RTU, optional 0-1kHz (proportional to flow) - Sensor response time: 1 second - Temperature transmitter: 0°–130°F (-18°...55°C) - Gas temperature: Standard 0°–150°F (-18°...66°C) Optional 0°–250°F (-18°...121°C) - Pressure range Inline measurement: 500 PSI ~ 34.5 Bar - Pressure range Inserted measurement: 225 PSI ~ 15.5 Bar - Power supply: 24VDC-250mA / 230VAC-50mA...
... cell RS232 Communication RS485 Communication (Option) Real-Time Clock (Option) TECHNİCAL SPECİFİCATİONS CLASS III OIML R-76 approval reset Tare Negative measurement Auto-scan Reset at boot Manual reset Animal weighing mode Multi-range weighing Metric / Imperial conversion Battery level indication, the low battery warning 3 point orange RS-232 (RS 485 optional) Optional relay control output (i5indicators do not support this feature) optional Date / Output with Clock Ability Simple counterbalance Internal battery (i5 indicators are without battery)...
Germany, Langquaid
... modules ("EXPANSION MODULES") can be added, each capable of accommodating up to two additional optional cards. The product has been developed according to the strictest vibration standards, features up to 71 configurable I/O ports as well as START and STOP, and supports serial interfaces: RS-232/485, CANopen, Profibus DP, PROFINET, EtherCAT®, and EtherNet/IP™.
...Based on the latest microprocessor technology Automatic impedance and frequency adjustment Adjustable output power between 40% and 100% of the nominal power of the ultrasonic generator Automatic maintenance of the set output power RS232 interface and optional RS-485 fieldbus connection (ProfiNet, Profibus, DeviceNet, CANopen, etc.) Frequency range: 25, 40, 58, 75, 132, 192 kHz Compact...
...Four-Channel Power Supply / Display + Operates four flow meters, controllers, vacuum gauges, and more + Simultaneously displays four channels with measurement units and gas types + Analog: 0-5 VDC, 0-10 VDC, 4-20 mA + RS-232/RS-485 + Ratio control for gas mixing + Totalizer function...
Germany, Hohen Neuendorf Ot Bergfelde
...Small T90 time through micromechanically manufactured Si sensor Universally applicable hardware base, high measurement range dynamics (e.g., 0 to 1%, 0 to 100%, 95 to 100% H2) Integrated cross-gas correction, no external calculation required Open interface architecture (RS 485, RS 232, PROFIBUS) SIPROM GA network for maintenance and service information (optional)...
Türkiye, Yenimahalle/ankara
... memory - Displaying measurement, configuration and history (logged) data on the built-in indicator (LCD) and outputting the data to the external devices via M-BUS interface or RS-485 interface - Configuring the flow meter according to on-site and process requirements - Monitoring and indicating alarm conditions (ER, error situations) and faults; recording error and fault types and intervals into the corresponding logs - Protecting logged data and configuration settings from unauthorized access, -R400 -MAP16 -EN ISO 4064, -OIML 49, -RO-2275-15356 (TYPE APPROVAL)...
... Reliability and warranty The FV-40 is equipped with cutting-edge technology for optimized detection and better resistance to false alarms while optimizing costs. All models are certified in accordance with current regulations. They come standard with a heated optic that eliminates the risks of freezing and condensation, adjustable sensitivity, and communication options that adapt to user needs: 3-color LED, 0-20mA, HART® protocols, RS-485, and MODBUS®.
France, Rambouillet
...-404 offers a comprehensive solution to optimize your operations. Modbus Connectivity and 1-Wire Sensors: The X-404 enables extensive monitoring through Modbus RS-485 connectivity for up to 32 devices and the 1-Wire Bus for up to 16 temperature and humidity sensors. You can easily view and adjust Modbus/RS-485 registers via its built-in firmware.
France, Saint Martin Du Bois
... (tariffs or external alarms) - RS-485 Modbus/RTU communication Voltage measurement: 300 Vac phase-neutral / 520 Vac phase-phase 50...60 Hz Current measurement: ITF: ... /5A or /1A | MC: ... /250 mA Accuracy V, I: 0.5% (without transformer) Accuracy kW, kWh: 1% (without transformer) Protection: IP65 front Safety: Class III according to EN 61010 Protection against electric shock by double insulation class II Standards: IEC 61000, IEC 61000-4-3, IEC 61000-4-11, IEC 61000-4-4, IEC 61000-4-5, measurement according to MID, UL...
...mounting holes Output signal: CANopen, CAN SAE J1939, SSI, RS-485 Supply voltage: 5 V, 10...32 V Material: aluminum, stainless steel Protection level: IP67, maintenance-free, shock-resistant, heavy-duty, harsh environments, impact-resistant, EMC Application area: industry, OEM, robotics, systems, machinery, equipment manufacturing, medical technology, renewable energy sources Additional features: high resolution, high precision, programmable, high speed, battery-free, True-Power-On...
ufs.country_names.RU, Moscow
... battery charge voltage allows extending its service life. EPU case made in the standard format of a 19" telecommunication rack with a height of only 2U, which ensures its compact placement. Remote monitoring of operation via RS-232/485 and SNMP is possible.
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play