...Infrared spectroscopy can be used to characterize organic substances (e.g., plastics, lubricants, oils, elastomers, fibers) and simple mixtures. In addition to the examination using FTIR spectroscopy to characterize organic substances, their thermal properties can be investigated using DSC. If mixtures are present, analysis using gas chromatography coupled with mass spectrometry provides further insights into the composition and also allows for the differentiation of very similar substances.
Austria, Engerwitzdorf
...The CO2 sensors EE893 and EE892 have been specifically designed for OEM applications and demanding environmental conditions. The multi-point CO2 and temperature calibration ensures excellent measurement accuracy across the entire temperature range. Due to their low power consumption, compact design, and electrical connection options via contact pins and connectors, the EE893 and EE892 modules are ideally suited for integration into battery-operated devices.
Switzerland, Reinach Bl
... affected by changing media, temperature changes, gas blankets or vapors. Measuring Principle:Guided radar Characteristic / Application:Basic device; Rod probe, Rope probe; Integrated data memory, Factory precalibrated, Reliable measuri Supply / Communication:2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus); 4-wire (HART) Accuracy:Rod probe: +/- 2 mm (0.08 in); Rope probe: +/- 2 mm (0.08 in) Ambient...
Germany, Bruchsal
...This has the advantage that the user does not need to know which gas type is in the IG unit. On the display the gas concentration of the gas sample is shown. A rechargeable battery can be integrated as an option, which enables the devices to also be used directly on the construction site. A sample is injected with a gas syringe. This offers the advantage that only minimal gas quantities are required and you can check the function of the gas analyser yourself.
Germany, Bühl
...LiquiScale is an advanced level measuring device in IP65 design for pressurized liquid gas tanks. Our measurement system features drift-stable differential pressure technology (drift over 10 years less than 0.3%) and reliably monitors the level as well as the tank head pressure. The large, brightness-adjustable LED display allows for easy reading in the dark and from distances of over 5 meters...
...Suction system for one or two measuring points: Measurement gas supply and transmitter in a wall-mounted housing.
Germany, Melle
...The WARP 100 is an inline pipe measurement system for wall thickness and diameter measurement at up to 38 measurement points and 19 axes. More than 1100 measurements per second ensure continuous measurement. This is particularly important for pipes with high quality standards, such as pressure or gas pipes. The maximum line speed for 100% coverage is up to 11.8 m/min. The WARP 100 is available in...
Germany, Betzigau
...• Reliable measurement principle and easy commissioning. • High chemical resistance of the probe. • High sensitivity starting from a DK value of ≥1.5. • Level measurement independent of the container wall or pipe. • Maintenance-free, corrosion-resistant, suitable for a variety of applications. • Approvals for use in gas and dust explosive areas. • Level detection in liquids, sludges, foams...
Austria, Olbendorf
...4-20mA, RS 485 Modbus RTU, optional 0-1kHz (proportional to flow) - Sensor response time: 1 second - Temperature transmitter: 0°–130°F (-18°...55°C) - Gas temperature: Standard 0°–150°F (-18°...66°C) Optional 0°–250°F (-18°...121°C) - Pressure range Inline measurement: 500 PSI ~ 34.5 Bar - Pressure range Inserted measurement: 225 PSI ~ 15.5 Bar - Power supply: 24VDC-250mA / 230VAC-50mA...
...The EcoSonic X12 is a modern ultrasonic gas meter approved for trade measurement. It is available in sizes DN80 to DN400, in pressure ratings PN10 to PN100, or up to ANSI600.
United Kingdom, Bedfordshire
Switzerland, Greifensee
...With Tunable Diode Laser and SIL2 Compliance - New Approaches for Gas Analytics. GPro 500 TDL Series Interference-free and drift-free TDL technology ensures better process control and lower maintenance costs. However, reliable measurement with a TDL is often hindered by necessary conditions such as minimum optical path length, the presence of a purge gas, and/or maximum dust load. Considering...
Germany, Hohen Neuendorf Ot Bergfelde
...Measurement ranges from 0 … 10 to 0 … 80 g/Liter Output signal 4 … 20 mA, two-wire Temperature compensated and hermetically sealed, thus no influence from temperature fluctuations, altitude differences, and air pressure variations Parts in contact with the measuring substance and housing made of stainless steel, fully welded Protection class IP 67, field housing, excellent long-term stability, high interference immunity...
Germany, Gießen
...With Tunable Diode Laser and SIL2 Compliance - New Approaches for Gas Analytics. GPro 500 TDL Series Interference-free and drift-free TDL technology ensures better process control and lower maintenance costs. However, reliable measurement with a TDL is often hindered by necessary conditions such as minimum optical path length, the presence of a purge gas, and/or maximum dust load. Considering...
Germany, Augsburg
...The EPC Spot is our measuring device for a random check of the gas levels of O2/CO2 in packaging or packaging machines. A sample is taken by a special needle. Due to the small amount of gas the analyser needs for the measurement, blister packs or ampoules can also be tested. As a user, you can enter...
...Gas sensor for toxic gases with electrochemical measuring cell and output signal 0..10V Application: Monitoring air for toxic gas concentrations Advantages: Low cross-sensitivity to other gases Suitability: Dusty, dirty environments Housing: Aluminum, LxWxH 90x80x80mm Protection class: IP65, EMC protection Gas entry: Diffusion, sinter filter, protection class IP44 Output signal: 0..10V, linear, temperature compensated Power supply: 12-36V DC...
Germany, Villingen-Schwenningen
...The robust insertion sensor VA 550 is the ideal flow sensor for uncomplicated consumption measurement in existing compressed air or gas pipelines from 3/4" to DN 500. The sensor can be easily installed and removed under pressure via a ½" ball valve. — Robust impact-resistant aluminum die-cast housing for outdoor use IP 67 — All media-contacting parts made of stainless steel 1.4571 — Suitable for...
France, La Fleche
...Accuracy: +/- 0.1% full scale (FS)\n- 'Peak' function: sampling at 5,000 Hz\n- Indicators: low battery, unit of measurement, overload...\n\nFeatures:\n- IP 65 waterproofing (IP 67 optional)\n- Long-lasting battery powered, user-replaceable\n- All stainless steel sensor\n- Completely maintenance-free\n- Standardized 1/4 male gas connection"}...
...The ExoFlex™ line of exothermic gas generators is designed to generate lean or rich exothermic gas. The generator includes automatic output turndown to 20% of the generator capacity with little loss of efficiency using the patented, maintenance-free ExoInjector™ gas mixing system. Thanks to a patented fuel injection technology that utilizes electronic flow measurement and precise ratio control...
Italy, Maracalagonis
...-calibration procedure: the term and concept may horrify some metrologists, but the operation is very interesting, as well as absolutely original. I invite anyone who may be curious to contact us: they will receive all the necessary information to assess the quality of our innovation. Being the latest addition to the BetaCAP series, this diluter is built with more advanced electronics: the measurement resolution has increased from 12 to 16 bits, and the interface features a color graphic display with a touch screen.
Germany, Bad Wünnenberg
... for the 4 Pa test and even »NEW AND UNIQUE« a wood moisture content measurement function to VDI Guideline 4206 (VDI = Association of German Engineers). * Effective condensate protection * Automatic CO clean out pump protects CO sensor (Wöhler A 550) * 4-filter technology – easily accessible * Analyzer and sensor diagnostics * Sensor replacement – user-friendly * Rechargeable battery operating time: more than 12 h with Lithium Ion power * Hose assembly – robust and flexible...
Austria, Wien
...With Tunable Diode Laser and SIL2 Compliance - New Approaches for Gas Analytics. GPro 500 TDL Series Interference-free and drift-free TDL technology ensures better process control and lower maintenance costs. However, reliable measurement with a TDL is often hindered by necessary conditions such as minimum optical path length, the presence of a purge gas, and/or maximum dust load. Considering...
...Achieve optimal preparation of the gas to be analyzed with the patented gas conditioning system GOT.
...HONOLD - Dealer German Manufacturer & Service Precise Sampling Air Sampling Gas Sampling Borehole Probe Gas Analyzer for Soil Air and Process Gas Measurement...
...The deltaflow differential pressure probe is a precision flow measurement system for steam, gas, and liquids in pipelines. The deltaflow flow measurement has been continuously developed over the years. We not only utilize our own expertise but also collaborate with renowned institutions, such as the Chair of Fluid Mechanics at the University of Erlangen, the National Metrology Institute, the...
Switzerland, Düdingen
...For pipe nominal diameters: DN 13 – DN 4500 Flow range: 0.03 to 12.2 m/s Temperature range: -40 to +150°C Advantages - Optional: Data logger / ATEX approval - Suitable for contaminated or gas-containing liquid media - Measurement accuracy ± 2 % of the measured value - Cost-effective, quick, and non-intrusive installation - Applicable to various pipe materials...
ufs.country_names.RU, Moscow
... functions of diagnostics, adjustment, calibration and operational control of measurement accuracy. Depending on analytical applications, GAOS MS process mass spectrometers are equipped with various modifications of the sample preparation system. Continuous sampling of the gas probe under conditions: - Temperature up to 1200 °C; - Dust content up to 30 g/m3; - Pressure (10-3÷3...
Germany, Kirchzarten
... scalable from 10 .. 100 % within a measurement range Measurement accuracy:±0.2 % or ±0.5 % FS (Measurement accuracy for the reference 0.3 Pa, for measuring ranges ≤ ±1.5 kPa) Medium:Natural gas Housing for surface mounting:Protection class IP 65 also for top-hat rail mounting Output:0 .. 10 V, 0/4 .. 20 mA, ± 5 V Power supply:24 VDC...
France, Ste Hélène Du Lac
...FOR VOLUMETRIC METER Male / female stainless steel GAS BSP tube with length Lg = 5 x DN Welded stainless steel 304 polished fitting and sleeve ALLOWS FOR SMOOTHING THE FLOW UPSTREAM AND DOWNSTREAM OF THE METER TO OPTIMIZE MEASUREMENT ACCURACY Reference: MCLRMF034 Material: Stainless Steel 304...
France, Lacq
...Design and manufacturing according to ASME MFC12M standard Liquid, gas, steam flow measurement High rangeability due to the unique streamlined shape of the probe Double averaging for improved accuracy Minimal unrecoverable pressure loss Monoblock construction of the probe for optimal robustness Long-term accuracy, no wear No drift over time for better stability Repeatability and reliability of the measuring element Suitable for flow measurement in large pipes, for installations with low pressure loss...

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play