... components on the sensor housing, including the end faces, must be avoided. The measuring element consists of a membrane that lies perpendicular to the sensor axis, on the inner side of which a full bridge of strain gauges is applied, expecting a stable supply voltage and having a nominal value of approximately 1 mV/V. The connection cable is routed radially out of the housing through a sleeve that...
... valves (from MR 290), optionally spring-loaded single ball valves. . Safety: Separation chamber with drain pipe between dosing head and gearbox protects against leaks. . Flexible stroke adjustment: Manually or electrically (ATE) adjustable. Optional extensions: . Double dosing pumps for increased performance. . Stroke counting with inductive sensor for precise batch processes. . Frequency converter control for variable control.
Germany, Thierstein
... stainless steel ball housing also possesses, in addition to its high protection class IP 67, all the features for residue-free and antibacterial cleaning. Features: — Nominal pressures: 0 ... 160 mbar to 0 ... 20 bar — Accuracy: 0.1 % FSO — Turn-Down 1:5 — Hygienic design — Front-flush mounted capacitive ceramic sensor — Diverse process connections (inch threads, clamp, etc.) — Integrated display and operating module — Separation membrane Al2O3 99.9 % Optional features: — Explosion protection Intrinsically safe design (ia) — HART® communication...
Germany, Henfenfeld
...Ceramic Sensors Pressure Sensors with membrane thicknesses up to 0.12 mm, media resistant Sensor Holders for smoke detectors in aircraft construction Temperature Sensors for over-temperature protection, air conditioning, temperature measuring devices...
Switzerland, Ebnat-Kappel
...The IST AG MicroFlowSens (MFS) technology was developed for fast flow measurements. Due to the membrane system, the thermal mass is reduced to the minimum resulting in a very fast response time and low power consumption. In addition to measuring flow rates, the MicroFlowSens offers an outstanding sensitivity and is able to detect flow direction. The MFS flow sensor is optimal for limited space...
Germany, Hohen Neuendorf Ot Bergfelde
...Measuring ranges: 0 … 400 mbar to 0 … 40 bar Accuracy: 0.1 % FSO Excellent temperature behavior of 0.04 % FSO / 10 K (≤ 0.04 % FSO / 10K) Hygienic process connections Vacuum-proof Signal processing of the sensor signal using digital electronics...
Germany, Mainz
... on the other side with the Al2O3 of the membrane, which has excellent chemical resistance. Using O-rings, the sensor can be easily integrated into valve blocks or similar applications. The special feature of these ceramic sensors is that for differential pressure measurements, only one differential sensor is needed instead of two relative pressure sensors. Therefore, only a single error needs to be considered, which improves the overall accuracy of the system.
France, Chateaufort
...Small-sized membrane sensor. Total insulation by silicone oil cushion. Protection against polarity reversal and integrated lightning protection (except for model 1660). Total liquid tightness, robust and reliable construction. Very high measurement sensitivity (on the order of a millimeter). 4-20 mA converter integrated into the sensor or remote depending on the version. Electrical insulation...
Germany, Donaueschingen
...:<±1% RH Response time humidity:<12 s with membrane filter Tk residual error:0.05% RH/K (at 0...+60 °C) Long-term drift humidity:<0.5% RH/a Humidity measuring principle:capacitive polymer humidity sensor Temperature measuring range:-40...+125 °C Accuracy:±0.2 °C (at 0...60 °C) Reproducibility temperature:±0.1 K Response time temperature:<12 s Long-term drift temperature:<0.05 K/a Temperature...
Germany, Duisburg
... offers a 4…20 mA output and optional HART®7 for user-friendly configuration. The level probe is also available with an integrated Pt100 temperature sensor. Protection level:: submersible Medium:: for liquids Additional features:: stainless steel Protection level:: submersible Level range:: 1…20 m / 3.3…65.6 ft Process pressure:: 0.1…10 bar / 1.45…145 psi...
Germany, Heddesheim
...The iNet Sensor® QPHE-C-95 pH electrode with ceramic membrane combines pH and reference components in a single sensor, making it very easy to handle. Accurate | Stable | Reliable The iNet Sensor® QPHE-C-95 pH electrode with ceramic membrane combines pH and reference components in a single sensor, making it very easy to handle. The integrated temperature sensor allows for simultaneous...
France, Huningue
...Digital pressure transmitter sensor with oil-free ceramic cell for measurement in gases or liquids The Cerabar PMC71 digital pressure transmitter sensor with oil-free capacitive ceramic measuring cell is typically used in process and hygienic industries for measuring pressure, level, or volume in liquids and gases. It ensures high system safety thanks to the ceramic membrane resistant to vacuum...
Germany, Meinerzhagen
...Temperature controllers of the teco series cd are designed for the operation with water and direct cooling up to 95 °C or 120 °C. The temperature of the process water is controlled automatically. A temperature sensor, installed inside the unit, measures available actual temperature. The microprocessor control with membrane keyboard or touchscreen operation compares measured value and...
France, La Mulatière
... connection is achieved through a standard ANSI flange by default. Pressure mode: relative Measurement range: 0-60 mbar to 200 bars Accuracy: ±0.1% (up to ±0.075%) ±0.25% ±0.5% Temperature: Ambient: -40 to 85°C Storage: -40 to 90°C Process: -25 to 85°C Power supply: 12 to 45V DC (24 V DC is recommended) Output: 4-20mA / HART Display: LED with multiple parameters ATEX: Exia II CT6 Exd II CT4 Materials: Housing: low copper content aluminum cast, epoxy powder coating Sensor: Stainless steel 316 Protection: IP67...
Switzerland, Bad Ragaz
...The Fast Combination pH Electrode with Temperature Sensor from Vuille pH Electrodes AG redefines efficiency for accurately determining pH values in aqueous and partially aqueous media. With the innovative integration of a temperature sensor beneath the pH glass membrane, this electrode sets new standards in speed and accuracy. Features: - Rapid Temperature Stabilization: The temperature sensor...
Germany, Bad Oeynhausen
...The DAP Series incorporate a heated sensor tip, which limits the potential for sensor damage relating to the membrane, resulting from installation or removal of the pressure transmitter. The Gneuss patented heated sensor tip allows the sensor to be easily removed from a “frozen” melt without any problems. The diaphragm is not damaged when the polymer contracts. The DAP has revolutionized the handling of critical medias, for example PC, PMMA or ABS. Pressure type:absolute...
...UniBar pressure sensors measure the relative pressure of various media in closed systems within the range of -1...600 bar. • Easy operation via the display • Flush-mounted for easy cleaning • Space-saving process connection due to small pressure membrane • Highly visible switching status indicator UniBar pressure sensors measure the relative pressure of various media in closed systems within the...
Germany, Villingen-Schwenningen
...The dew point set is pre-wired and ready to plug in right out of the box. The alarm values can be freely set. Advantages of dew point measurement for adsorption dryers / membrane dryers: — Plug-and-play system: everything is pre-wired and ready to go — No need for extensive study of the operating manual — 2 alarm contacts (230 VAC, 3 A) for pre-alarm and main alarm, freely adjustable — 4...20 mA analog output — Alarm option: siren and red continuous light...
...Process pressure measurement in pipelines and containers » Robust and durable – stable even at temperatures up to 150 °C (302°F) » Compact design, stainless steel membrane 316L, without display » Process connection hygienic thread G1" (CLEANadapt), Tri-Clamp 1.5" or 2" » Fast response time » Available with relative or absolute measuring cell Please contact us for further information or a quote.
Luxembourg, Echternach
... opening ● Spring closes – control air opens ● Spiral support in stainless steel Variants ● Spring opens – control air closes ● Control air opens – control air closes ● Drive housing made of hard-anodized aluminum ● High-temperature version with FKM/FPM seal (Recommendation: >= 80 °C measured at the drive housing) Options ● Position feedback sensor ● Position controller...
France, Marcy-L'etoile
... Pendular level sensors for solids: Simple and reliable sensor for powders forming a cone in the silo. Does not require a power supply. Conductive level sensors for liquids: Level sensor capable of controlling up to two levels. Available with the following power supplies: 115-230VAC, 24-48VAC, 24VDC. Floating level sensors for liquids: These models do not require an electrical power supply. Versions for agressive environments and food processing.
Switzerland, Greifensee
...Reliable Ozone Monitoring in the Sanitization of Pure Water The advanced design features and durable measurement technology of the pureO3 sensor for dissolved ozone ensure the most precise and reliable ozone measurements down to zero ppb. The innovative combination of membrane, cathode, and electrolyte in the sensor provides fast, reliable measurement data with greater stability for various pure water applications.
Switzerland, Reinach Bl
...Total chlorine consists of free and combined chlorine, making it a good indicator of disinfectant residues in effluent. The total chlorine sensor CCS120D ensures reliable monitoring of total chlorine limits in the discharge. It reduces your maintenance effort, as it allows for easy replacement of the electrolyte and membrane cap. Thanks to the digital Memosens technology, the CCS120D offers the highest process and data security. It withstands corrosion and moisture, can be calibrated in the laboratory, and enables predictive maintenance.
Austria, Wien
...Reliable ozone monitoring in the sanitization of pure water The advanced design features and durable measurement technology of the pureO3 sensor for dissolved ozone ensure the most precise and reliable ozone measurements down to zero ppb. The innovative combination of membrane, cathode, and electrolyte in the sensor provides fast, reliable measurement data with greater stability for various pure water applications.
... gases in industrial production and process engineering. Storage and operation can occur between -20 and 85 °C. The exceptionally high detectivity of up to 4.0*10^8 cm√Hz/W, as well as the very high sensitivity of up to 200,000 V/W, provide extraordinary signal quality in the field of pyroelectric detectors. Two sensor chips with a thin-film CPM membrane form the core of the dual detector MPS2SENS...
Germany, Kirchzarten
... sensor. The device contains no parts subject to wear or mechanical friction. The PU/PI/PIZ is specifically designed for use in ventilation and air conditioning systems, for monitoring filling levels and filters. The optional 3 or 4-digit liquid crystal display allows for the visualization of measured values not only in Pa, kPa, but also, for example, in mmWs. Thanks to the optional time constant of 5...
Belgium, Gavere
...The pressure sensors from Clicktouch are based on a unique modern technology that converts pressure, weight, and force into electrical resistance. They resemble the design of membrane keypads and flexible circuits, making them lightweight with a thin, low profile. The pressure sensor and interface have a simple structure and can be used even in extreme temperatures. With typical values ranging...
Spain, Montcada
... individual customer requirements. The vertical opening/closing system of the membrane frame prevents the displacement of materials while it closes and allows access to the parts from all sides of the press, which is particularly important for working with large and complex 3D shapes. The temperature sensor allows for optimal process monitoring and controls the automatic temperature mode. Additionally, two adjustable air turbines accelerate the cooling process after the pressing process.
... options · RoHS compliant User-specific designs · Discs made of stainless steel · Cylindrical measuring bodies with metal membrane · Pressure sensors are supplied according to user specifications, in accordance with the measuring body requirements.
Germany, Ratingen
... panel or for wall mounting. As an option, the following extensions of the indicator are possible: Indicator with up to two adjustable red or green limit value pointers. TECHNICAL SPECIFICATIONS: Operating Mode: Measuring Mode Measuring Substance: Air or non-aggressive gases Measuring Sensor: Mechanical membrane measuring instrument Measuring Unit: Pa Minimum Measuring Span: 0…100Pa (1mbar...
Popular countries for this search term

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store