...Cast resin transformers from 100 kVA to approximately 20 MVA and oil transformers from 3.5 MVA to about 20 MVA up to 36 kV for low and high voltage motors to reduce network load during the starting process. For low and high voltage motors to reduce network load during the starting process.
Germany, Bünde
...Our low-voltage systems are designed for the safe and efficient distribution of low-voltage electricity. They offer flexible configuration options and are ideal for commercial buildings, industrial facilities, and infrastructure projects. High reliability and safety are guaranteed.
...They are filter reactors used to reduce the current harmonics (THDI) in the network installation to the values required by the standards. It is used in Reactive Power Compensation systems to limit the overcurrents that occur during the switching of the capacitor groups and to protect the capacitors. ●Harmonic Filter Reactors ●Copper and Aluminum winding ●High efficiency sheet core ●Varnishing under vacuum ●Oven drying at high temperature ●Three Phases and single Phase Frequency:50 Hz. +/-%5 (60 Hz. optional) Operating Temperature:-10 °C ~ +40 °C height:1.500m...
Germany, Steinenbronn
...ENT.A current transformers convert a high primary current into a manageable low 5A secondary current. The current transformers can also be used for potential-free measurement of AC currents. Features Primary current depending on model Secondary current 5 A Rated power 5 VA Conductor passage Ø 20 mm Rail 30x10 mm Accuracy class 1...
Germany, Hohen Neuendorf Ot Bergfelde
... expansion module (RS232, BACNET, ETHERNET) Current input 1A or 5A – connection to external current transformers (transformer ratio (CT) adjustable) Voltage: 80…500V (Phase-Phase) – direct or with voltage transformer (transformer ratio (VT) adjustable) Auxiliary voltage: 80…265Vac/110…300Vdc or 11…60Vdc...
... energy and register it in up to two energy tariffs. It is an indoor meter designed as a built-in device for DIN rail mounting, with a compact design of only 4 modular units. The EcoCount SL 85 is available for direct connection with a maximum current of 85 A in low-voltage networks. The EcoCount SL 5/1 is intended for connection to current transformers with 5 A or 1 A secondary current in low-voltage networks.
...The single-phase control transformers CTA are special types of isolation transformers, typically used to power control circuits. These transformers have the characteristic of reducing short-circuit current in the event of a fault. They also allow the use of auxiliary circuits without grounding. They are transformers commonly used to power very low voltage safety circuits.
Germany, Heiligenstadt I.ofr.
...Type DSI Category Transformers Design Safety transformer (three-phase) Application For supplying electrical circuits or devices that are to be operated with safety extra-low voltage (SELV, max. 50 V) (e.g., portable tools). Execution open design (IP 00, installation max. up to IP 23) with two-chamber design for separated windings (safe separation) on foot brackets (DIN 41307) lying down finger...
... (over current, over heat, short circuit, low voltage) in mind, they have very low risk of failure and are very durable and long lasting. They are produced with single-phase and three-phase outputs, with frequencies of 50 Hz, 60 Hz, 83.3 Hz, suitable for 110 VAC, 220VAC and 380 VAC output voltage values." ...
Germany, Au / Hallertau
...the air and creepage distances and test voltage comply with VDE 0570. Transformers from these series are not short-circuit proof. Measures against overload and short circuits must be taken by the user! For the PS series, a version with an integrated PTC resistor is available. This makes these transformers short-circuit proof. In the event of an overload, the PTC resistor limits the primary current. After the overload is removed and the transformer has cooled down, it is ready for operation again.
...Busbars are typically used in high current, low voltage distribution and control equipment. Typical busbar applications include busway systems, low and medium voltage switchgear, transformers, earthing, electrification - lines panel boards, switchboards, and feeds to heavy electrical uses in commercial and industrial buildings - such as plating cells and feeder systems. Busbars can be made from...
United Kingdom, Hull
... coupling to the secondaries (shield is internally grounded to the end bell). • Windings: Concentric wound for low stray field and low noise. • Models: This series is an upgrade from the entire 200 Series range of units PLUS 2 models designed specifically for 300B tubes (Part number 300BX) and 2A3 tubes (Part Number 302AX). • Finish: Black powder paint to match the 1650 Series of output transformers • Units can be run full wave bridge or full wave C.T. • Conservative designs - CSA certified (209651).
Germany, Hilden
... (transparent) for external supply in rail/cable systems, supplied loose. SEC connections optionally as front-side plug connections or side-exit connection cables. Primary side thermal switch at 130°C. NTC inrush current limiter and side-accessible, flush-mounted glass tube fuse 5 x 20 mm. Optional with current monitor (STR) or switching module technology (UM). Input voltage: 230 V ± 10% according to IEC 38 Output voltage: 11.5 V (under rated conditions) Mains frequency: 50-60 Hz Power ratings: 200, 300, 400 VA Ambient temperature: max. ta 60°C...
Germany, Langenbach
...The low voltage transformer from BETA Elektrotechnik offers precise conversion of medium voltage to low voltage for safe energy distribution in industrial and commercial applications. This transformer is characterized by its high reliability and compact design. It is the ideal solution for power distribution networks in buildings, factories, and public infrastructures, where a constant and safe power supply is crucial. Benefits: - Precise conversion of power - High reliability - Compact design - Suitable for industrial applications - Efficient energy distribution...
...Aesthetic appearance LCD screen Quiet operation environmental design Easy installation Simple program menu Ability to charge all batteries (VRLA, GEL, LEAD ACID) 24-hour operation, Parallel operation Automatic activation in case of power failure Low warning voltage error High warning voltage error Operation at different frequencies (50 - 60 Hz)...
Romania, Popesti Leordeni
...We can build or install any type of low-voltage electrical installation system necessary for a commercial building (hotel, offices, medical, fit-out), industrial space, or residential area. We are committed to providing you with a safe and efficient electrical installation that will meet your needs. We are accredited by ANRE type C1B and C2B, which ensures that your electrical installation...
...The coupling capacitor blocks the alternating current frequency and its harmonics, but transmits the high-frequency PLC signals. Coupling capacitors allow intelligent low-voltage transformers with powerline communication (PLC) connectivity to be coupled at high frequency with neighboring transformers without PLC connectivity, thereby expanding the PLC supply area with minimal additional effort.
...Three-phase AC regulators with thyristor control for the operation and control of single-phase and three-phase electric furnaces at low voltage with temperature regulation. DSH The DSH unit can perform a mixed ignition with initial operation in phase angle and subsequent full-wave operation. Phase angle ignition is typically used with three-phase inductive loads such as transformers or with...
Switzerland, Wil
... / max. output current: 24.0 VDC / 11.0 ADC Product Features • Step-up and step-down converter without isolation • Very low input voltage ripple • Permanently short-circuit and overload proof • For ambient temperatures from -40°C to +85°C • Thermal shutdown at +90°C • Only for passive loads • Integrated EMI input and output filter • No power derating • Heat-dissipating metal plate • Robust design • Unipolar output voltage...
... copper wire in brown glass fabric insulating tube, ~20cm long - Output connection: solid copper wire in glass fabric insulating tube, ~20cm long Input voltage: 230V~ Output power: 2x 110VA Weight: 2.3kg Rated frequency: 50-60Hz Output voltage: 2x 30V~ Output current: 2x 3.67A...
Bulgaria, Shabla
...The subject of the activity of the company "ELPROM EMZ" in the city of Shabla includes: 1) Charging stations for electric vehicles, electric buses, electric mopeds, electric motorcycles, and electric bicycles. 2) Current measuring transformers for low voltage up to 1 kV and medium voltage up to 24 kV, for indoor installation with accuracy classes of 0.2, 0.2S, 0.5, 0.5S, and 5P10, and rated power...
Ukraine, Uzhgorod
Czechia, Prague
Czech-based manufacturer Vikodek offers low voltage measuring current transformers for various purposes such as: • separating low-voltage metering devices and relays from primary current in the electrical grid, ensuring the safety of electrical appliances during maintenance and diagnostics. • supplying power for a chain of relay protection. • electric power metering through electrical energy meters.
Germany, Sulzbach-Laufen
...The name MBS stands for innovation and know-how "Made in Germany". Our product range includes current and voltage transformers for low and medium voltage, harmonic measurement, as well as residual current monitoring. Among other things, our offerings also include Rogowski coils, energy meters, energy management, and current transformers for AC/DC, voltage transformers, shunt resistors, busbar...
France, Frasne
TESLA BOBINAGE is a company specialized in the design, development, and integrated industrialization of a wide range of transformers and inductors. We also manufacture low-voltage autotransformers, variable autotransformers, high-voltage transformers, current transformers, and electromagnetic inductors for vibration, gripping, and closure, as well as vibrator coils. Additionally, we offer...
Serbia, Zajecar
...;* Toroidal transformers;* System grounding metal resistors for medium voltage networks. FMT was privatised at the end of 2005. Since then we have made substantial investments to modernise production by acquiring new machines and equipment. We have continued to expand the variety of products with the development of a new range of voltage transformers (VTOP) for power supply of reclosers; and a new range of low voltage current transformers (STN). Other types of new products are in development.All products have been type tested and the company has a 100% testing regime. www.fmt.rs & boris@fmt.rs...
France, Cepoy
Measurement and protection transformers for Low and Medium Voltage up to 52kV, current and voltage sensors, toroidal current transformers, molded resin insulating parts, developments based on customer specifications. • Sectors of activity: Energy production, Energy transmission and distribution, Industry, Tariff metering, Railways, Marine, Mining, Tertiary.
... Analyzers, • NH (H.R.C.) Fuses, • Horizontal - Vertical Type Switch Fuses, • Measurement Devices, • Motor Protection Switches, • Capacitors, • Current Transformers, • Distribution Boards, Busbar Systems, • Cam Switches, • Electronic Energy Meters, • Natural Gas and Water Meters. Our products undergo rigorous testing hundreds of times in our internationally accredited 440 V 100kA short circuit laboratory. The quality and standards of our products are 50% - 100% higher than the IEC and EN norms.
Türkiye, Ankara
... completed 40 years, our company produces series of products such as panel-type measuring instruments, low voltage current transformers, low/medium/high voltage safety equipment, terminal blocks, and socket connectors, while also serving leading defense and aerospace companies both in our country and around the world. As a result of our efforts, we designed and produced a driver that operates in the...