Germany, Bünde
...Regular maintenance is crucial for the lifespan and efficiency of transformers. Our maintenance service includes comprehensive inspections, preventive maintenance work, and necessary repairs. We ensure that your transformers operate at their best and minimize unplanned outages.
... structure for hot-swappable power modules (being formed of IGBT modules) to get higher performance and reliability of critical situations. It is scalable from 30kVA to 900kVA with N+X modular architecture/parallel topology. RM series saves your energy thanks to self-aging function without connecting real loads during test procedure. Monitoring and managing RM series with the largest size of colorful touch screen that provides graphical and text based information for safer operation. All UPS system are fully supported by NECRON service team that assures reliable, preventive and corrective miss...
...The very compact function units of the 771 series are designed for direct installation in your device. Based on our single-phase ring transformers, we offer you an extensive range of hand- and motor-operated three-phase ring transformers as well as regulated three-phase AC power sources for the creation of continuously adjustable or stabilized power supplies. The units can be mounted flexibly and securely. Of course, we have ensured that nearly all dimensions fit within the 25mm grid of today's standard steel sheet enclosures.
...Voltage Optimization and protection function Energy Saving Feature Special management software for energy saving Maintenance-free Thyristor Technology Production in the power range of 10kVA – 1000kVA It can be produced as 1 Phase and 3 Phase Input Suitable for all industrial voltages Voltage reduction up to 30% Voltage boost up to 15% Response time: 20msec Voltage correction...
...Transformers in which one or more components are sealed and encapsulated in resin. This method allows the transformer to be protected from moisture, dirt, and other potentially harmful elements for its operation. This construction method enables the transformer to function perfectly even under particularly severe usage conditions, as the core and coil are better protected. Every phase of the...
Germany, Hilden
...Isolation transformers, safety transformers, power supplies for mounting on DIN rail TS 35. Function Description Isolation or safety transformers for mounting on DIN rail TS 35. The transformers are fully encapsulated in a plastic housing and comply with protection class II. As standard, the transformers are equipped with a primary side device protection fuse 5 x 20 mm. Available upon request...
Italy, Villa Guardia
...-150Vac & 4-300Vac o SS [1-phase input and output] o SS [1.5kVA - 3kVA – 5kVA - 7.5 kVA] o Frequency Regulation included [40Hz-80Hz] o LCD 7’’ touch screen o Current Regulation included o Sensing function included • Communication Interfaces (Remote Control): o Physical Interfaces: RS-232, Ethernet, 12 poles I/O o Communication protocols: SCPI (over RS-232 and Ethernet), 0-10Vdc (over analog I/O 12 poles), o LabView Drivers ...
...the input voltage, the output voltage and the drawn amperage can be seen instantaneously. In addition. • Optionally : the controle module ‘’MSC-7203 + Wi-Fi ‘’İs available. - Output Voltage Range: 0-250V. - Input Voltage: 220v. - Full Function Multimeters. - Record the highest and lowest values seen. - Reset information. - Input output voltage and amperage calibration. - Voltage range from 0 to 250 Volt wide (in single phase). - Terminal or output socket. - Simple ...
... combination with its partial discharge-free design, the self-healing dielectric guarantees an extraordinarily long service life and maximum operational reliability. Unlike conventional oil-filled ALLFILM capacitors, where a breakdown in the dielectric inevitably leads to failure, the self-healing dielectric of the DSCTM immediately isolates the breakdown point; the capacitor continues to function as before.
France, Comines
...Injection Case Testing relays at maximum or minimum current or voltage. Testing Statimax (R) relays without auxiliary power supply. User-friendly, injection of single-phase AC current and voltage. Ideal for testing current transformers. Timer function, ammeter suitable for on-site applications.
...Minimum load/maximum load for resistive loads 10 W/1300 W On/Off switching: illuminated rocker switch, 2-pole switching Input: 230 V~ / 50/60 Hz Electronics: phase-cut control (symmetrical) Interference suppression: complies with EN standards Housing: plastic housing Weight: approx. 750 g Dimensions: 150 x 80 x 55 mm Options: potentiometer locking, stand mounting, additional function indicator light Load: Schuko socket, other plug connections such as those according to Swiss or French/Belgian standards...
Germany, Bad Saulgau
... with potential separation through built-in special transformer with interference protection function, or with potential-bearing output voltage. Main switch with / without emergency stop function. Short-circuit protection, overload protection with phase sensitivity. Optional with residual current and temperature monitoring, emergency stop, control and monitoring functions, multiple outputs, socket...
China, Shenyang
...designed by Microcyber Corporation is a gateway device for Modbus-RTU protocol and HART protocol. As Modbus master, G0310 Modbus to HART Gateway communicates with devices that have Modbus-RTU communication function via RS485 interface. It can convert device data to HART device variables output, and it also supports 4~20mAcurrent output. Connect different control systems (Siemens, Emerson, Schneider Electronics, ABB, Yokogawa, Rockwell, etc.)...
Italy, Cavenago Brianza
... most stringent technical requirements. The highest quality of the components used in the production of our rectifiers, combined with the ongoing research conducted by our electrical engineers, allows our equipment to function in any location and under any temperature conditions, maximizing their potential. The quality of our products is also reflected in the comprehensive documentation provided with the supply, with meticulous attention to the technical diagrams and maintenance booklets.
Türkiye, Kocaeli
... any kind of switching on-off. It can be mounted on the low voltage side of transformers on or in the board, on switchboards, at distribution panels and meets the various requirements of mining, navigation, etc. as well. Each switch consists of various on-off elements that can be easily assembled-disassembled according to the switching program. The casing of the switching on-off elements are made...
Popular countries for this search term