STRATE AWASTOP non-return valve
STRATE AWASTOP non-return valveSTRATE AWASTOP non-return valve

STRATE AWASTOP non-return valve

Due to their special design, 100 % free passage and low flow resistance, STRATE AWASTOP non-return valves are ideal for: Sewage technology, media with solids and coarse solids, sludge (up to 5 % TM) Fresh and service water technology, including in areas where high pressure losses make powerful pumps necessary On request: pumping of fluids deviating from the media listed Areas where quiet operation is particularly important Non-return valves are recognised all over the world as for universal applications in the pumping of fresh water, effluent, sludge and air. Stand for high operational safety Stand out thanks to their excellent value-for-money and low maintenance requirements 100 % free passage Low flow resistance Quiet operation thanks to the inclined valve seat which shortens the closing distance Minimum clogging tendency through optimum hydraulic design− Fail-safe closing of the valve since the closing element is fixed securely into the valve cover DN:50 - 300 PN:10 Housing:EN-GJL-250 (GG 25)
Similar products
1/15
STRATE sandwich-type non-return valves - SB
STRATE sandwich-type non-return valves - SB
The special lightweight aluminium design and silicone inserts of STRATE sandwich non-return valves SB makes them ideal for: Conveying air and gases u...
DE-31157 Sarstedt
STRATE EVA Relief valve
STRATE EVA Relief valve
Positive displacement blowers and single-stage screw compressors start up directly or following a star delta circuit if no gentle start or no frequenc...
DE-31157 Sarstedt
STRATE Valve shafts GRP
STRATE Valve shafts GRP
STRATE valve shafts are used in industrial and municipal areas. The different design sizes of the STRATE AWALIFT valve shafts allow the optimum size t...
DE-31157 Sarstedt
STRATE level measuring systems pressure tube (SR)
STRATE level measuring systems pressure tube (SR)
Measurement using the impact pressure method Measuring range 0 – 0.5 mWS Connection via polyamide flange with quick-action elbow gland Enclosure ratin...
DE-31157 Sarstedt
STRATE Alarm unit AG 230/12
STRATE Alarm unit AG 230/12
Mains-independent alarm unit for signalling a fault. Product features Powered by integrated 1.8 Ah 12 V battery in the event of a power failure Opti...
DE-31157 Sarstedt
STRATE Level measuring systems analogue sensor (AS)
STRATE Level measuring systems analogue sensor (AS)
Pressure sensor for analogue filling level measurement Supply voltage 24 V DC Output of an analogue measuring signal 4 – 20 mA Pressure ranges dependi...
DE-31157 Sarstedt
STRATE AWALIFT 0/2
STRATE AWALIFT 0/2
The AWALIFT 0/2 double installation with proven STRATE system conforms to the requirements of DIN 1986-100 and DIN EN 12056-4. The installation forms ...
DE-31157 Sarstedt
STRATE Level measuring system HWWS (only for spare parts requirements)
STRATE Level measuring system HWWS (only for spare parts requirements)
Closed pneumatic-mechanical switching system The sewage-resistant pressure bellows and the end membrane are connected via a pneumatic line routed in a...
DE-31157 Sarstedt
STRATE AWALIFT 0/1
STRATE AWALIFT 0/1
The AWALIFT 0/1 requires a space of just 1200 mm x 1200 mm or d=1500 mm. Thanks to its unique design, it can be installed in even non-standard install...
DE-31157 Sarstedt
STRATE Level measuring system HWAS-BN
STRATE Level measuring system HWAS-BN
Redundant twin measuring system where there is a requirement for increased operational safety for sewage pumping stations (e.g. main pumping station) ...
DE-31157 Sarstedt
STRATE Flow measurement Magnetic-inductive – for reliable and economic recording
STRATE Flow measurement Magnetic-inductive – for reliable and economic recording
Magnetic-inductive flow measurement allows the precise measurement of electrically conductive liquids such as sewage. Standard measuring values are th...
DE-31157 Sarstedt
STRATE Level measuring system HWAS
STRATE Level measuring system HWAS
Pressure sensor for analogue filling level measurement Especially suitable for STRATE sewage pumping stations for municipal applications Supply voltag...
DE-31157 Sarstedt
STRATE AWAcontrol 2DF 2 plus level controller
STRATE AWAcontrol 2DF 2 plus level controller
the economical alternative Replacement for STRATE 1DF2 and 2DF2 pump controllers suitable for connection to all STRATE fill level recording systems: c...
DE-31157 Sarstedt
STRATE AWALIFT 2/2 flach
STRATE AWALIFT 2/2 flach
Anywhere small quantities of wastewater need to overcome a high discharge head is the perfect application for the flattened version of the AWALIFT 2/2...
DE-31157 Sarstedt
STRATE AWAcontrol Compact Control System 2DF master
STRATE AWAcontrol Compact Control System 2DF master
2DFmaster AWAcontrol control system for STRATE sewage pumping stations with two pumps each and an installed overall motor rating of 0.75 kW to 75 kW e...