Power Products X700UC2_208 Generator Set, equipped with an MTU engine and an alternator.
Direct access to sections
GENERAL FEATURES
General characteristics
Description
Power table
Engine type 12V2000G45E
Frequency (Hz) 60
Reference voltage (V) 208/120
Max ESP power (kVA) 871
Max ESP power (kWe) 696.80
Max PRP power (kVA) 791.80
Max PRP power (kWe) 633.50
Current (A) 2418
Standard cabinet TERMINAL
Optional cabinet M80
Optional cabinet TELYS
Optional cabinet APM802
Electronic regulation
Mechanically welded chassis with anti-vibration suspensions
Radiator with mechanical fan (see performance table for temperature)
Exhaust compensator(s) with flanges
Starter and 24V charging alternator
Delivered with oil and coolant -30°C
User and commissioning manual
Voltages ESP PRP Amperes
backup
kWe kVA kWe kVA
208/120 697 871 633 792 2418
ENGINE FEATURES
General data
Exhaust
Fuel
Oil
Thermal balance
Intake air
Cooling system
Emissions
Engine brand MTU
Engine ref. 12V2000G45E
Aspiration type Turbo
Intake air cooling Air/Air DC
Number of cylinders 12
Cylinder arrangement V
Displacement (L) 23.89
Bore (mm) 130
Stroke (mm) 150
Compression ratio 16
Speed (RPM) 1800
Piston speed (m/s) 9
ESP power (kW) 780
Regulation class (%) +/- 0.5%
BMEP (bar) 19.80
Regulation type Electronic
Exhaust gas temperature @ ESP 60Hz (°C) 535
Exhaust gas flow @ ESP 60Hz (L/s) 2500
Exhaust back pressure (mm H2O) 500
Consumption 110% (L/h) 191
Consumption 100% load (L/h) 174
Consumption 75% load (L/h) 131
Consumption 50% load (L/h) 90
Max fuel pump flow (L/h) 480
Oil capacity (L) 77
Min oil pressure (bar) 4.70
Max oil pressure (bar) 7.50
Oil consumption 100% load (L/h) 1.74
Oil sump capacity (L) 67
Heat rejected in exhaust (kW) 553
Radiated heat (kW) 40
Heat rejected in water (kW) 275
Max intake back pressure (mm H2O) 150
Combustion air flow (L/s) 1000
Engine and radiator capacity (L) 180
Max water temperature (°C) 102
Water outlet temperature (°C) 95
Fan power (kW) 43
Fan air flow Dp=0 (m3/s) 20.61
Available back pressure on air (mm H2O) 20
Refrigerant type Glycol-Ethylene
HT thermostat (°C) 75-88
PM emission (g/kW.h) 0.03
CO emission (g/kW.h) 0.46
HC emission (g/kW.h) 0.10
ALTERNATOR FEATURES
General data
Other data
Alternator ref. AT02640T
Number of phases Three-phase
Power factor (cos Phi) 0.80
Altitude (m) 0 to 1000
Overspeed (rpm) 2250
Number of poles 4
Insulation class H
Temperature class (H/125°) continuous 40°C H / 125°K
AVR type R450
Total harmonic distortion at no load THD (%)
Waveform: NEMA = TIF
Waveform: IEC = FHT
Number of bearings 1
Direct coupling
Voltage regulation at steady state (+/- %) 0.50
Continuous rated power 40°C (kVA) 720
Backup power 27°C (kVA) 871
Efficiency at 100% load (%) 93.80
Air flow (m3/s) 1.20
Short circuit ratio (Kcc) 0.2660
Unsaturated synchronous longitudinal reactance (Xd) (%) 444
Unsaturated synchronous transverse reactance (Xq) (%) 226
Transient no-load time constant (T'do) (ms) 2039
Saturated transient longitudinal reactance (X'd) (%) 19.80
Transient short circuit time constant (T'd) (ms) 100
Saturated subtransient longitudinal reactance (X''d) (%) 15.90
Subtransient time constant (T''d) (ms) 10
Subtransient time constant (T''q) (ms) 10
Saturated subtransient transverse reactance (X''q) (%) 18.20
Unsaturated homopolar reactance (Xo) (%) 0.50
Saturated inverse reactance (X2) (%) 17.06
Armature resistance (Ra) (%) 0.0150
Armature leakage reactance (Xa) (%) 0.99
Armature time constant (Ta) (ms) 15
No-load excitation current (io) (A) 0.63
Load excitation current (ic) (A) 3.06
Load excitation voltage (uc) (V) 36.20
Response time (Delta U = 20% transient) (ms) 500
Starting (Delta U = 20% permanent or 50% transient) (kVA) 1285.39
Transient Delta U 4/4 load-Cos Phi 0.8 AR (%) 14
No-load loss (W) 10847.81
Heat dissipation (W) 36517.68
DIMENSIONS
Dimensions compact version
Dimensions soundproof version
Length (mm) 3971
Width (mm) 1848
Height (mm) 2150
Net weight (kg) 5143
Tank capacity (L) 0
Soundproofing type M427
Length (mm) 6400
Width (mm) 2170
Height (mm) 2721
Net weight (kg) 8130
Tank capacity (L) 930
Sound pressure level @1m dB(A) 93
Sound pressure level @7m dB(A) 84
CABINET
TERMINAL
M80, information reporting
TELYS, ergonomic and user-friendly
APM802 dedicated to energy center management
The cabinet serves as a simple terminal for connecting an electrical cabinet.
It offers the following features:
Emergency stop button, customer connection terminal, CE compliance.
The M80 cabinet has a dual function. It serves as a simple terminal for connecting an electrical cabinet and as a dashboard with direct reading, where the dials allow monitoring of the basic parameters of your generator set.
It offers the following features:
Engine parameters: Tachymetry, Hour meter, Water temperature indicator, Oil pressure indicator, Emergency stop button, Customer connection terminal, CE compliance.
Extremely versatile, the TELYS cabinet is complete yet remains very accessible due to in-depth work on optimizing ergonomics and user-friendliness. With a large display screen, buttons, and a scrolling knob, it opts for simplicity and emphasizes communication.
It offers the following features:
Electrical measurements: Voltmeter, Ammeter, Frequency meter.
Engine parameters: Hour meter, Oil pressure, Water temperature, Fuel level, Engine speed, Battery voltage.
Alarms and faults: Oil pressure, Water temperature, No start, Overspeed, Min/max alternator, Min/max battery voltage, Emergency stop, Fuel level.
Ergonomics: Navigation knob between different menus.
Communication: Control and remote operation software, USB connections, PC connection.
For more information about the product and its options, please refer to the commercial documentation.
The new APM802 control cabinet is dedicated to the operation and monitoring of energy centers for the hospital, data center, banking, oil and gas, industrial, IPP, rental, and mining markets.
This cabinet is standard on all generator sets from 275 kVA intended for coupling functions. For the rest of our range, it is optional.
The human-machine interaction, designed in collaboration with a company specializing in interaction design, facilitates operation with a 100% touch screen. The pre-configured system for energy center applications features a unique customization function compliant with the international standard IEC 61131-3. New communication functions (automation and regulation) enhance the high availability of the installation's equipment.
Highlights:
Dedicated to energy center management.
Ergonomics specially designed
High availability of equipment
Guaranteed modularity and sustainability
Facilitated installation extension
For more information, please refer to the commercial documentation.