Sensor controller ANATOM78S..EEX in ATEX - AWAX 26XXL EEX and EEX3
Sensor controller ANATOM78S..EEX in ATEX - AWAX 26XXL EEX and EEX3

Sensor controller ANATOM78S..EEX in ATEX - AWAX 26XXL EEX and EEX3

Atex and machine safety management in a compact 45 mm format Atex dual-channel insulation barrier and controller for built-in machinery safety Atex safety ATEX standards EN 60079-0 EN 60079-11 EN 60079-25 EN 60079-26 ATEX marking [Ex ia] IIC Ga [Ex ia] IIIC Da II(1)GD Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor Machine Safety Performance level with AWAX controller: PL = e in accordance with ISO 13849-1 Safety category: 4 in accordance with ISO 13849-1 Time before dangerous failure: MTTFd = 120 years Cycle before dangerous failure: B10d=100,000 at 5A Risk duration: 20 ms max. Cable severing protection: yes (opening of safety lines) Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting. Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs Reset: configurable by dip-switch (SR=Automatic, N=manual) Mounting: symmetrical DIN 35mm rail on DIN 50022 Mounting: IP 54 electrical box Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum Temperature: -20°C to +40°C. Certification: INERIS 06ATEX0007X
Similar products
1/15
RMA42 Process Transmitter with Control Unit
RMA42 Process Transmitter with Control Unit
The process transmitter indicates, analyzes, and calculates analog measurement values. With loop power supply, it can power two-wire technology sensor...
CH-4153 Reinach Bl
SINEAX VB604s - Programmable temperature transmitter
SINEAX VB604s - Programmable temperature transmitter
• Measurement of DC voltage, DC current, temperature (RTD, TC) and resistance • Programmable remote I/O functionality. Readout of all input variable...
CH-5610 Wohlen
C-box/2a Controller - Interface and signal processing units
C-box/2a Controller - Interface and signal processing units
C-Box/2A is used for fast D/A conversion of two digital input signals or for evaluating two digital sensor signals. Output of the sensor signals is po...
DE-94496 Ortenburg
SINEAX A230S / Multifunctional Power Meter / Network Analysis
SINEAX A230S / Multifunctional Power Meter / Network Analysis
Multifunctional Power Meter with Network Analysis 96 x 96 mm...
DE-90449 Nürnberg
Interface Technology - Analog Signal Isolator
Interface Technology - Analog Signal Isolator
For the separation, transformation, processing, conversion, and adjustment of analog signals, our program offers the appropriate interface device for ...
DE-45472 Mülheim
Signal Converter, Signal Transducer
Signal Converter, Signal Transducer
Signal Converter SK20 from SSI to Analog 0...10V, 0/4...20mA Conversion of SSI data to analog devices. 16-bit resolution, 1ms conversion rate. Zoom/w...
DE-88045 Friedrichshafen
MDR-137-P / MDR-337-P
MDR-137-P / MDR-337-P
Pressure control module with integrated power amplifier and optional automatic commissioning assistant...
DE-41372 Niederkrüchten
AS-i 3.0 PROFINET Gateway with integrated... - BWU2828
AS-i 3.0 PROFINET Gateway with integrated... - BWU2828
Up to 32 release circuits, secure outputs are supported, 1 safety monitor for 2 AS-i circuits, applications up to category 4/PLe/SIL 3, chip card for ...
DE-68199 Mannheim
ROBA®-SBCplus
ROBA®-SBCplus
Safe Brake Control ✓ Applicable up to PLe and SIL CL3 ✓ Safely switches two brakes ✓ Control and power sections separated ✓ Overexcitation time config...
DE-87665 Mauerstetten
Inductive Sensors - Analyzers for Ex Sensors - Inductive Sensors - Analyzers for Ex Sensors
Inductive Sensors - Analyzers for Ex Sensors - Inductive Sensors - Analyzers for Ex Sensors
The EGE evaluation electronics for Ex proximity detectors complement the intrinsically safe sensors from EGE. They are used for setting the switching ...
DE-24214 Gettorf
BMSD‑40Modbus - Brush DC motor Modbus controller
BMSD‑40Modbus - Brush DC motor Modbus controller
BMSD‑40Modbus controllers are designed to control a DC brush motor with rated current up to 40 Amp, maximum limit current 100A. The controllers regula...
EE-12618 Tallinn
Residual current monitors - IL 5882
Residual current monitors - IL 5882
• According to IEC/EN 62 020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A •...
DE-78120 Furtwangen
Interface Devices
Interface Devices
Where digital signals need to be galvanically isolated and processed, or where a galvanically isolated supply voltage limited in voltage and current i...
AT-1150 Wien
Siemens Plc Automation Sinaut - Siemens PLC automation SINAUT
Siemens Plc Automation Sinaut - Siemens PLC automation SINAUT
Siemens PLC automation The following options are available for the PLC automation from the SIMATIC S7, SIPLUS S7, SIMATIC ET 200, SIMATIC C7, SIMATIC...
DE-63457 Hanau
Temperature Monitoring Relay RH41M / NTC Input
Temperature Monitoring Relay RH41M / NTC Input
Temperature Monitoring Relay RH41M / NTC Input / Marine Approval - Limit Switch for Temperature (NTC). Simple application; designed for harsh operatin...
DE-90429 Nürnberg

The europages app is here!

Use our improved supplier search or create inquiries on the go with the new europages app.

Download in the App Store

App StoreGoogle Play