Продукти за soma rn 79984 (3)

Nova-K52

Nova-K52

It is a chelated liquid potash that facilitates the availability of potassium. Being completely soluble, its application is very fast and is immediately assimilated by the plant. Improves the organoleptic quality of fruits, vegetables and industrial crops, as well as the coloration of the flowers of ornamental plants. Applied at the end of the vegetative phase (before harvesting or harvesting) it advances ripening, increases resistance to drought and climatic adversities. The presence of an adequate dose of chelating agent guarantees the total availability of potassium, regardless of the quality of the water used for foliar and fertigation treatments SKU:n/a Size:1000 LITERS, 20 LITERS, 5 LITERS
Таванска противопожарна врата EI 60 - противопожарна врата

Таванска противопожарна врата EI 60 - противопожарна врата

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboard Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018 Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Таванска противопожарна врата 120 MN - противопожарна врата

Таванска противопожарна врата 120 MN - противопожарна врата

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018 Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.