Таванска противопожарна врата EI 60 - противопожарна врата

Таванска противопожарна врата EI 60 - противопожарна врата

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboard Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018EN 1634-1: +A1: 2018 Fire dampers EI 60 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 60. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.
Стомана за защита от взривове - Ramor® 400

Стомана за защита от взривове - Ramor® 400

Les tôles Ramor® ont des propriétés balistiques excellentes, alliées à une haute dureté et résistance. La gamme Ramor® 400 est conçue pour des applications qui nécessitent une protection contre les explosions.
SD 510 II

SD 510 II

Dégauchiseuse raboteuse professionnelle Equipements et caractéristiques standard Largeur d'usinage 510mm Réglage fin de hauteur de rabotage par volant Longueur totale des tables 2250 mm Diamètre d'arbre 100 mm, 4 fers de 510 mm Table de rabotage : 1050 x 510 mm Hauteur de rabotage 250 mm Affichage mecanique hauteur de table rabot (compteur SIKO) 2 Vitesses d'avance: 6 and 12 m /min Inclinaison de guide 45° à 90° (Sur butée) Montée et baisse électrique de table de rabotage Démarrage auto étoile triangle Poids: 900 kg
Таванска противопожарна врата 120 MN - противопожарна врата

Таванска противопожарна врата 120 MN - противопожарна врата

Frame made of aluminium profile bars connected by "Tox" connections - All-round EPDM lip seal - Restraint security - Hidden latches - Screwed GKF gypsum plasterboards Tested for fire resistance from underneath (room side) NF EN 1634-1: +A1: 2018 Fire dampers EI 120 are designed to be installed in false ceilings for self-contained fire protection, one of the requirements being "combustible load only on the room side" and the fire resistance class being EI 120. They provide effective protection against the progression of fire from the room into the false ceiling area. The integrated aluminium frame is equipped with a fire stop. The cover of the inspection hatch is fitted with a DF fire protection plate and protected against smoke entry by a versatile all-round seal. The cover is secured on both sides by automatic safety hooking arms.