Продукти за клапан 4 pvc (2)

Protech AC-P : Акрилна боя, миеща се, за интериори и екстериори

Protech AC-P : Акрилна боя, миеща се, за интериори и екстериори

Protech AC-P Paint based on acrylic resins in aqueous emulsion, for interiors and exteriors, protective lamellar structure which, in addition to having an aesthetic effect, allows maximum filling, transpiration and very high resistance to mechanical and chemical light. The high coverage and expandability make this product extremely easy to apply. The special acrylic resins that compose it allow to obtain a film characterized by a rapid insensitivity to water even during the drying phase, with a consequent reduction of the "snail effect" in the event of atmospheric events. Protective and decorative finish painting of walls, facades, concrete products, plasters, masonry, natural stone, porous substrates in general. For old plasters, pay particular attention to the old pre-existing paints, which must be removed by careful scraping and brushing in order to obtain a healthy and non-friable support; then proceed with the application of Protech Fix AC fixative. When applying on new plasters, it is good practice to insulate the base with acrylic insulator or even better with a white or neutral microemulsion fixative. Avoid windy or cold days when applying. Do not apply on fresh or particularly alkaline substrates, respect a minimum carbonation period of at least four weeks. On large surfaces it is recommended to apply product from the same batch and always proceed wet on wet to avoid signs of recovery. Never operate with temperatures below + 5 ° C. Rainy weather, excessive atmospheric humidity and temperatures below + 8 ° C can greatly compromise drying with the possibility of washing off by rainwater even after several days. . DILUTION (by volume with drinking water) BRUSH 1st COAT: 15% a crossed coat or two coats 12-24 hours apart 2nd COAT: 10%. ROLLER 1st COAT: 10% 2nd COAT: 10%. SPRAY (through specific equipment) 1st COAT: 15/25% 2nd COAT: 15/25%. To avoid filming defects, being resin-based products in aqueous emulsion, the application temperature must be between + 5 ° C and + 35 ° C with relative humidity not higher than 60/70%. Do not apply under the direct action of the sun and wind. Do not apply on fresh or particularly alkaline substrates, respect a minimum drying period of the substrate of at least four weeks. It is also advisable for colored, not to use on large surfaces dyed with different production batches as slight differences between batch and batch are technically possible. Please check the color before application as we will not respond to any disputes regarding the shade of the applied product. From 0.20 to 0.30 liters of Protech AC-P for each square meter of surface to be painted. Pail 14 l
Syntech HAG Acryl: Акрилна инжекционна смола с ниска вискозитет за запечатване на пукнатини

Syntech HAG Acryl: Акрилна инжекционна смола с ниска вискозитет за запечатване на пукнатини

Syntech HAG Acryl Syntech HAG Acryl is a four-component resin that reacts to form an elastic and durable gel. The properties of Syntech HAG Acryl are: • Good general chemical resistance. • Does not contain acrylamide, methacrylamide, formaldehyde or solvents. • Not inflammable. • Excellent adhesion on mineral building materials such as concrete, cement and bricks. • The reaction speed can be adjusted from a few seconds to several minutes. • When the injected cracks dry out due to temperature or groundwater level fluctuations the gel does not crack easily. • The hardened gel has excellent durability in wet-dry cycles. Syntech HAG Acryl components are supplied ready to use. Create 2 mixes in separate plastic buckets. Prepare only the quantity to be used each time. Solution 1: Syntech HAG Acryl component A (25 kg resin) mixed with Syntech HAG Acryl component B (2.5 kg catalyst). Solution 2: Syntech HAG Acryl component C (2 packs of 0.625 kg) mixed with clean tap water. Attention: The amount of water must be equal in volume to solution 1. When mixing resin, always use a wooden or stainless steel spatula. The reaction time depends on the temperature of the material, the structure of the building and the possible amount of water present. Higher temperature will speed up the reaction time and lower temperature will slow it down. It is advisable to carry out an on-site test, before injection, to observe and define the reaction time. To change the reaction time, only adjust the amount of Syntech HAG Acryl component C. The amount of the other components remains the same. Use a two-component stainless steel pump (manual, electric or pneumatic). Check that the pump and equipment are clean and that there is no residue from previous injection work. The two mixtures are fed into the pump separately, but are mixed homogeneously at a volumetric ratio of 1:1 in the pump's mixing head, before being injected through the pump nozzle. Check the quality of the concrete, as injection involves pressure. Sealing and waterproofing of cracks and cavities in walls, floors, concrete constructions, underground structures, etc. It can be used in constructions that are not permanently in contact with water (fluctuating groundwater level). Injection of very fine cracks. Determine the type and size of packers based on your pump and injection type. If reinforcing steel is present, try to locate it and plan the drilling pattern so that the reinforcement is not drilled. Drill holes at an angle of approximately 45° or less and in the direction of the crack. Make sure the hole goes through the crack. The distance of the drilled holes depends on the width of the crack. Place the packer in the hole. Prepare the pump to start the injection. The injection pressure varies depending on the structure and size of the crack. Start the injection at the lowest point of the crack. Continue injecting until resin flows out of adjacent packer(s). This is necessary to achieve uniform distribution of the material. Stop pumping, unplug and move on to the next packer. Continue the procedure until the crack is completely filled. After the material has cured, the packers can be removed. Holes drilled can be covered with Repar Tix Speedy HP quick-setting mortar. Clean and rinse the pump equipment with water whenever there is a stoppage longer than 15 minutes and, after completing the injection, rinse with a sufficient amount of water. Make sure the pump is clean and stop only when clean water comes out of the pump. The consumption of the product depends on the size of the empty volume to be filled. Can 25 kg [A] - Plastic can 2.5 kg [B] - Canister 0.625 kg [C] - Canister 0.625 kg [D] - Kit: 1 Can 25 kg [A] + 1 Plastic can 2.5 kg [B] + 1 Canister 0.625 kg [C] + 1 Canister 0.625 kg [D]